{ "indications": [ { "name": "Insufficient disk space", "description": "Build node or EBS volume is out of disk space, rerun build with CLEAN_WORKSPACE parameter", "comment": "Build node or EBS volume is out of disk space, clean build node or the EBS volume", "single_line": true, "find_all": false, "log_patterns": [ "^.*No space left on device.*$" ], "log_testcases": [ "error: unable to open output file '...': 'No space left on device'" ], "owners": [] }, { "name": "Build node disconnected", "description": "Build node disconnected during the build", "comment": "Build node disconnected during the build, rerun the job", "single_line": true, "find_all": false, "log_patterns": [ "^.*Agent went offline during the build.*$" ], "log_testcases": [ "Agent went offline during the build" ], "owners": [] }, { "name": "Incremental build script error", "description": "Incremental build script error, merge latest from upstream", "comment": "Incremental build script error, merge latest from upstream", "single_line": true, "find_all": true, "log_patterns": [ "^.*File.*incremental_build_util\\.py\", line \\d+.*$" ], "log_testcases": [ "File \"scripts\\build\\bootstrap\\incremental_build_util.py\", line 87" ], "owners": [] }, { "name": "Corrupt PDB file", "description": "Corrupt PDB file, try build again with build parameter CLEAN_OUTPUT_DIRECTORY enabled", "comment": "Corrupt PDB file, try build again with build parameter CLEAN_OUTPUT_DIRECTORY enabled", "single_line": true, "find_all": true, "log_patterns": [ "^.*fatal error LNK1285: corrupt PDB file.*$" ], "log_testcases": [ "LINK : fatal error LNK1285: corrupt PDB file 'D:\\workspace\\o3de\\build\\windows_vs2019\\bin\\profile\\o3de.pdb'" ], "owners": [] }, { "name": "Case sensitive/insensitive issue", "description": "Once case changed in file name, run a clean build to fix the build failure.", "comment": "Once case changed in file name, run a clean build to fix the build failure", "single_line": true, "find_all": true, "log_patterns": [ "^.*ModuleNotFoundError: No module named 'Prefab.*$" ], "log_testcases": [ "ModuleNotFoundError: No module named 'Prefab" ], "owners": [] }, { "name": "Jenkins build node connectivity issue", "description": "Jenkins cannot reconnect to build nodes after Jenkins server restart.", "comment": "Jenkins cannot reconnect to build nodes after Jenkins server restart.", "single_line": true, "find_all": false, "log_patterns": [ "^Killed part of.*after waiting for.*because we assume unknown agent.*is never going to appear$" ], "log_testcases": [ "Killed part of O3DE ยป PR-9504 #2 after waiting for 5 min 0 sec because we assume unknown agent EC2 (us-west-2) - WIN2019_INC_3 (i-05a91a7e645fc20d1) is never going to appear" ], "owners": [] } ] }