@@ -1251,15 +1251,15 @@ uses
|
|
|
if assigned(hp) then
|
|
|
begin
|
|
|
current_module:=hp;
|
|
|
- { remove the old unit }
|
|
|
- loaded_units.remove(hp);
|
|
|
- hp.reset;
|
|
|
- { try to reopen ppu }
|
|
|
- hp.search_unit(s,fn,false);
|
|
|
{ try to load the unit a second time first }
|
|
|
- current_module.in_second_load:=true;
|
|
|
Message1(unit_u_second_load_unit,current_module.modulename^);
|
|
|
second_time:=true;
|
|
|
+ current_module.in_second_load:=true;
|
|
|
+ { remove the old unit }
|
|
|
+ loaded_units.remove(current_module);
|
|
|
+ current_module.reset;
|
|
|
+ { try to reopen ppu }
|
|
|
+ tppumodule(current_module).search_unit(s,fn,false);
|
|
|
end
|
|
|
else
|
|
|
{ generates a new unit info record }
|
|
@@ -1317,7 +1317,11 @@ uses
|
|
|
end.
|
|
|
{
|
|
|
$Log$
|
|
|
- Revision 1.23 2002-08-19 19:36:42 peter
|
|
|
+ Revision 1.24 2002-10-04 20:13:10 peter
|
|
|
+ * set in_second_load flag before resetting the module, this is
|
|
|
+ required to skip some checkings
|
|
|
+
|
|
|
+ Revision 1.23 2002/08/19 19:36:42 peter
|
|
|
* More fixes for cross unit inlining, all tnodes are now implemented
|
|
|
* Moved pocall_internconst to po_internconst because it is not a
|
|
|
calling type at all and it conflicted when inlining of these small
|