errord.msg 104 KB

12345678910111213141516171819202122232425262728293031323334353637383940414243444546474849505152535455565758596061626364656667686970717273747576777879808182838485868788899091929394959697989910010110210310410510610710810911011111211311411511611711811912012112212312412512612712812913013113213313413513613713813914014114214314414514614714814915015115215315415515615715815916016116216316416516616716816917017117217317417517617717817918018118218318418518618718818919019119219319419519619719819920020120220320420520620720820921021121221321421521621721821922022122222322422522622722822923023123223323423523623723823924024124224324424524624724824925025125225325425525625725825926026126226326426526626726826927027127227327427527627727827928028128228328428528628728828929029129229329429529629729829930030130230330430530630730830931031131231331431531631731831932032132232332432532632732832933033133233333433533633733833934034134234334434534634734834935035135235335435535635735835936036136236336436536636736836937037137237337437537637737837938038138238338438538638738838939039139239339439539639739839940040140240340440540640740840941041141241341441541641741841942042142242342442542642742842943043143243343443543643743843944044144244344444544644744844945045145245345445545645745845946046146246346446546646746846947047147247347447547647747847948048148248348448548648748848949049149249349449549649749849950050150250350450550650750850951051151251351451551651751851952052152252352452552652752852953053153253353453553653753853954054154254354454554654754854955055155255355455555655755855956056156256356456556656756856957057157257357457557657757857958058158258358458558658758858959059159259359459559659759859960060160260360460560660760860961061161261361461561661761861962062162262362462562662762862963063163263363463563663763863964064164264364464564664764864965065165265365465565665765865966066166266366466566666766866967067167267367467567667767867968068168268368468568668768868969069169269369469569669769869970070170270370470570670770870971071171271371471571671771871972072172272372472572672772872973073173273373473573673773873974074174274374474574674774874975075175275375475575675775875976076176276376476576676776876977077177277377477577677777877978078178278378478578678778878979079179279379479579679779879980080180280380480580680780880981081181281381481581681781881982082182282382482582682782882983083183283383483583683783883984084184284384484584684784884985085185285385485585685785885986086186286386486586686786886987087187287387487587687787887988088188288388488588688788888989089189289389489589689789889990090190290390490590690790890991091191291391491591691791891992092192292392492592692792892993093193293393493593693793893994094194294394494594694794894995095195295395495595695795895996096196296396496596696796896997097197297397497597697797897998098198298398498598698798898999099199299399499599699799899910001001100210031004100510061007100810091010101110121013101410151016101710181019102010211022102310241025102610271028102910301031103210331034103510361037103810391040104110421043104410451046104710481049105010511052105310541055105610571058105910601061106210631064106510661067106810691070107110721073107410751076107710781079108010811082108310841085108610871088108910901091109210931094109510961097109810991100110111021103110411051106110711081109111011111112111311141115111611171118111911201121112211231124112511261127112811291130113111321133113411351136113711381139114011411142114311441145114611471148114911501151115211531154115511561157115811591160116111621163116411651166116711681169117011711172117311741175117611771178117911801181118211831184118511861187118811891190119111921193119411951196119711981199120012011202120312041205120612071208120912101211121212131214121512161217121812191220122112221223122412251226122712281229123012311232123312341235123612371238123912401241124212431244124512461247124812491250125112521253125412551256125712581259126012611262126312641265126612671268126912701271127212731274127512761277127812791280128112821283128412851286128712881289129012911292129312941295129612971298129913001301130213031304130513061307130813091310131113121313131413151316131713181319132013211322132313241325132613271328132913301331133213331334133513361337133813391340134113421343134413451346134713481349135013511352135313541355135613571358135913601361136213631364136513661367136813691370137113721373137413751376137713781379138013811382138313841385138613871388138913901391139213931394139513961397139813991400140114021403140414051406140714081409141014111412141314141415141614171418141914201421142214231424142514261427142814291430143114321433143414351436143714381439144014411442144314441445144614471448144914501451145214531454145514561457145814591460146114621463146414651466146714681469147014711472147314741475147614771478147914801481148214831484148514861487148814891490149114921493149414951496149714981499150015011502150315041505150615071508150915101511151215131514151515161517151815191520152115221523152415251526152715281529153015311532153315341535153615371538153915401541154215431544154515461547154815491550155115521553155415551556155715581559156015611562156315641565156615671568156915701571157215731574157515761577157815791580158115821583158415851586158715881589159015911592159315941595159615971598159916001601160216031604160516061607160816091610161116121613161416151616161716181619162016211622162316241625162616271628162916301631163216331634163516361637163816391640164116421643164416451646164716481649165016511652165316541655165616571658165916601661166216631664166516661667166816691670167116721673167416751676167716781679168016811682168316841685168616871688168916901691169216931694169516961697169816991700170117021703170417051706170717081709171017111712171317141715171617171718171917201721172217231724172517261727172817291730173117321733173417351736173717381739174017411742174317441745174617471748174917501751175217531754175517561757175817591760176117621763176417651766176717681769177017711772177317741775177617771778177917801781178217831784178517861787178817891790179117921793179417951796179717981799180018011802180318041805180618071808180918101811181218131814181518161817181818191820182118221823182418251826182718281829183018311832183318341835183618371838183918401841184218431844184518461847184818491850185118521853185418551856185718581859
  1. #
  2. # $Id$
  3. # This file is part of the Free Pascal Compiler
  4. # Copyright (c) 1998-2000 by the Free Pascal Development team
  5. #
  6. # German (alternative) Language File for Free Pascal
  7. #
  8. # See the file COPYING.FPC, included in this distribution,
  9. # for details about the copyright.
  10. #
  11. # This program is distributed in the hope that it will be useful,
  12. # but WITHOUT ANY WARRANTY; without even the implied warranty of
  13. # MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.
  14. #
  15. #
  16. # The constants are build in the following order:
  17. # <part>_<type>_<txtidentifier>
  18. #
  19. # <part> is the part of the compiler the message is used
  20. # asmr_ assembler parsing
  21. # asmw_ assembler writing/binary writers
  22. # unit_ unit handling
  23. # scan_ scanner
  24. # parser_ parser
  25. # type_ type checking
  26. # general_ general info
  27. # exec_ calls to assembler, linker, binder
  28. #
  29. # <type> the type of the message it should normally used for
  30. # f_ fatal error
  31. # e_ error
  32. # w_ warning
  33. # n_ note
  34. # h_ hint
  35. # i_ info
  36. # l_ linenumber
  37. # u_ used
  38. # t_ tried
  39. # m_ macro
  40. # p_ procedure
  41. # c_ conditional
  42. # d_ debug message
  43. # b_ display overloaded procedures
  44. # x_ executable informations
  45. #
  46. #
  47. # General
  48. #
  49. # BeginOfTeX
  50. % \section{General compiler messages}
  51. % This section gives the compiler messages which are not fatal, but which
  52. % display useful information. The number of such messages can be
  53. % controlled with the various verbosity level \var{-v} switches.
  54. % \begin{description}
  55. general_t_compilername=01000_T_Compiler: $1
  56. % When the \var{-vt} switch is used, this line tells you what compiler
  57. % is used.
  58. general_d_sourceos=01001_D_Hostbetriebssystem: $1
  59. % When the \var{-vd} switch is used, this line tells you what the source
  60. % operating system is.
  61. general_i_targetos=01002_I_Zielbetriebssystem: $1
  62. % When the \var{-vd} switch is used, this line tells you what the target
  63. % operating system is.
  64. general_t_exepath=01003_T_Der Pfad der ausf�hrbaren Datei ist: $1
  65. % When the \var{-vt} switch is used, this line tells you where the compiler
  66. % looks for it's binaries.
  67. general_t_unitpath=01004_T_Der Unitpfad ist: $1
  68. % When the \var{-vt} switch is used, this line tells you where the compiler
  69. % looks for compiled units. You can set this path with the \var{-Fu}
  70. general_t_includepath=01005_T_Der Includepfad ist: $1
  71. % When the \var{-vt} switch is used, this line tells you where the compiler
  72. % looks for it's include files (files used in \var{\{\$I xxx\}} statements).
  73. % You can set this path with the \var{-I} option.
  74. general_t_librarypath=01006_T_Der Bibliothekspfad ist: $1
  75. % When the \var{-vt} switch is used, this line tells you where the compiler
  76. % looks for the libraries. You can set this path with the \var{-Fl} option.
  77. general_t_objectpath=01007_T_Der Objektdateienpfad: $1
  78. % When the \var{-vt} switch is used, this line tells you where the compiler
  79. % looks for object files you link in (files used in \var{\{\$L xxx\}} statements).
  80. % You can set this path with the \var{-Fo} option.
  81. general_i_abslines_compiled=01008_I_$1 Zeilen kompiliert, $2 Sekunden
  82. % When the \var{-vi} switch is used, the compiler reports the number
  83. % of lines compiled, and the time it took to compile them (real time,
  84. % not program time).
  85. general_f_no_memory_left=01009_F_Speicher voll
  86. % The compiler doesn't have enough memory to compile your program. There are
  87. % several remedies for this:
  88. % \begin{itemize}
  89. % \item If you're using the build option of the compiler, try compiling the
  90. % different units manually.
  91. % \item If you're compiling a huge program, split it up in units, and compile
  92. % these separately.
  93. % \item If the previous two don't work, recompile the compiler with a bigger
  94. % heap (you can use the \var{-Ch} option for this, \seeo{Ch})
  95. % \end{itemize}
  96. general_i_writingresourcefile=01010_I_Resourcestringtabellendatei $1 wird geschrieben
  97. % This message is shown when the compiler writes the Resource String Table
  98. % file containing all the resource strings for a program.
  99. general_e_errorwritingresourcefile=01011_E_Fehler beim Schreiben der Resourcestringtabellendatei: $1
  100. % This message is shown when the compiler encountered an error when writing
  101. % the Resource String Table file
  102. % \end{description}
  103. #
  104. # Scanner
  105. #
  106. % \section{Scanner messages.}
  107. % This section lists the messages that the scanner emits. The scanner takes
  108. % care of the lexical structure of the pascal file, i.e. it tries to find
  109. % reserved words, strings, etc. It also takes care of directives and
  110. % conditional compiling handling.
  111. % \begin{description}
  112. scan_f_end_of_file=02000_F_Unerwartetes Dateiende
  113. % this typically happens in one of the following cases :
  114. % \begin{itemize}
  115. % \item The source file ends before the final \var{end.} statement. This
  116. % happens mostly when the \var{begin} and \var{end} statements aren't
  117. % balanced;
  118. % \item An include file ends in the middle of a statement.
  119. % \item A comment wasn't closed.
  120. % \end{itemize}
  121. scan_f_string_exceeds_line=02001_F_Zeichenkette geht �ber Zeilenende hinaus
  122. % You forgot probably to include the closing ' in a string, so it occupies
  123. % multiple lines.
  124. scan_f_illegal_char=02002_F_Unzul„ssiges Zeichen
  125. % An illegal character was encountered in the input file.
  126. scan_f_syn_expected=02003_F_Syntaxfehler, $1 erwartet aber $2 vorgefunden
  127. % This indicates that the compiler expected a different token than
  128. % the one you typed. It can occur almost everywhere where you make a
  129. % mistake against the pascal language.
  130. scan_t_start_include_file=02004_T_Die Include-Datei $1 wird jetzt gelesen
  131. % When you provide the \var{-vt} switch, the compiler tells you
  132. % when it starts reading an included file.
  133. scan_w_comment_level=02005_W_Kommentarschachtelungstiefe $1 gefunden
  134. % When the \var{-vw} switch is used, then the compiler warns you if
  135. % it finds nested comments. Nested comments are not allowed in Turbo Pascal
  136. % and can be a possible source of errors.
  137. scan_n_far_directive_ignored=02006_N_$F Direktive (FAR) ignoriert
  138. % The \var{FAR} directive is a 16-bit construction which is recorgnised
  139. % but ignored by the compiler, since it produces 32 bit code.
  140. scan_n_stack_check_global_under_linux=02007_N_Stackpr�fung ist unter Linux global
  141. % Stack checking with the \var{-Cs} switch is ignored under \linux, since
  142. % \linux does this for you. Only displayed when \var{-vn} is used.
  143. scan_n_ignored_switch=02008_N_Compilerschalter $1 wurde ignoriert
  144. % With \var{-vn} on, the compiler warns if it ignores a switch
  145. scan_w_illegal_switch=02009_W_Compilerschalter $1 ist ung�ltig
  146. % You included a compiler switch (i.e. \var{\{\$... \}}) which the compiler
  147. % doesn't know.
  148. scan_w_switch_is_global=02010_W_Dieser Compilerschalter hat globale Auswirkung
  149. % When \var{-vw} is used, the compiler warns if a switch is global.
  150. scan_e_illegal_char_const=02011_E_Ung�ltige Char-Konstantante
  151. % This happens when you specify a character with its ASCII code, as in
  152. % \var{\#96}, but the number is either illegal, or out of range. The range
  153. % is 1-255.
  154. scan_f_cannot_open_input=02012_F_Datei $1 kann nicht ge”ffnet werden
  155. % \fpc cannot find the program or unit source file you specified on the
  156. % command line.
  157. scan_f_cannot_open_includefile=02013_F_Includedatei $1 kann nicht ge”ffnet werden
  158. % \fpc cannot find the source file you specified in a \var{\{\$include ..\}}
  159. % statement.
  160. scan_e_too_much_endifs=02014_E_Zu viele $ENDIF oder $ELSE Direktiven
  161. % Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced.
  162. scan_w_only_pack_records=02015_W_Record-Elemente k”nnen nur im Raster 1,2,4 oder 16 Bytes ausgerichtet werden
  163. % You are specifying the \var{\{\$PACKRECORDS n\} } with an illegal value for
  164. % \var{n}. Only 1,2,4 or 16 are valid in this case.
  165. scan_w_only_pack_enum=02016_W_F�r Aufz„hlungen k”nnen nur die Gr”áen 1,2 or 4 Bytes angegeben werden
  166. % You are specifying the \var{\{\$PACKENUM n\}} with an illegal value for
  167. % \var{n}. Only 1,2 or 4 are valid in this case.
  168. scan_e_endif_expected=02017_E_$1 erwartet f�r $2 definiert in Zeile $3
  169. % Your conditional compilation statements are unbalanced.
  170. scan_e_preproc_syntax_error=02018_E_Syntaxfehler im Argument einer $if Direktive
  171. % There is an error in the expression following the \var{\{\$if ..\}} compiler
  172. % directive.
  173. scan_e_error_in_preproc_expr=02019_E_Syntaxfehler im Kontext einer $if Direktive
  174. % There is an error in the expression following the \var{\{\$if ..\}} compiler
  175. % directive.
  176. scan_w_macro_cut_after_255_chars=02020_W_Inhalt des Makros wurde nach der Auswertung bei 255 Zeichen abgeschnitten
  177. % The contents of macros cannot be longer than 255 characters. This is a
  178. % safety in the compiler, to prevent buffer overflows. This is shown as a
  179. % warning, i.e. when the \var{-vw} switch is used.
  180. scan_e_endif_without_if=02021_E_ENDIF ohne IF(N)DEF
  181. % Your \var{\{\$IFDEF ..\}} and {\{\$ENDIF\}} statements aren't balanced.
  182. scan_f_user_defined=02022_F_Benutzerdefiniert: $1
  183. % A user defined fatal error occurred. see also the \progref
  184. scan_e_user_defined=02023_E_Benutzerdefiniert: $1
  185. % A user defined error occurred. see also the \progref
  186. scan_w_user_defined=02024_W_Benutzerdefiniert: $1
  187. % A user defined warning occurred. see also the \progref
  188. scan_n_user_defined=02025_N_Benutzerdefiniert: $1
  189. % A user defined note was encountered. see also the \progref
  190. scan_h_user_defined=02026_H_Benutzerdefiniert: $1
  191. % A user defined hint was encountered. see also the \progref
  192. scan_i_user_defined=02027_I_Benutzerdefiniert: $1
  193. % User defined information was encountered. see also the \progref
  194. scan_e_keyword_cant_be_a_macro=02028_E_Ein Makro, welches den selben Namen wie ein Schl�sselwort hat, wird ignoriert
  195. % You cannot redefine keywords with macros.
  196. scan_f_macro_buffer_overflow=02029_F_Makropuffer�berlauf w„hrend des Lesens oder Expandierens eines Makros
  197. % Your macro or it's result was too long for the compiler.
  198. scan_w_macro_deep_ten=02030_W_Expansion des Makros �berschreitet eine Makroschachtelungstiefe von 16
  199. % When expanding a macro macros have been nested to a level of 16.
  200. % The compiler will expand no further, since this may be a sign that
  201. % recursion is used.
  202. scan_e_wrong_styled_switch=02031_E_Compilerschalter in (* ... *)-Kommentaren sind nicht erlaubt
  203. % Compiler switches should always be between \var{\{ \}} comment delimiters.
  204. scan_d_handling_switch=02032_D_Bearbeite Schalter "$1"
  205. % When you set debugging info on (\var{-vd}) the compiler tells you when it
  206. % is evaluating conditional compile statements.
  207. scan_c_endif_found=02033_C_ENDIF $1 bearbeitet
  208. % When you turn on conditional messages(\var{-vc}), the compiler tells you
  209. % where it encounters conditional statements.
  210. scan_c_ifdef_found=02034_C_IFDEF $1 bearbeitet, $2
  211. % When you turn on conditional messages(\var{-vc}), the compiler tells you
  212. % where it encounters conditional statements.
  213. scan_c_ifopt_found=02035_C_IFOPT $1 bearbeitet, $2
  214. % When you turn on conditional messages(\var{-vc}), the compiler tells you
  215. % where it encounters conditional statements.
  216. scan_c_if_found=02036_C_IF $1 bearbeitet, $2
  217. % When you turn on conditional messages(\var{-vc}), the compiler tells you
  218. % where it encounters conditional statements.
  219. scan_c_ifndef_found=02037_C_IFNDEF $1 bearbeitet, $2
  220. % When you turn on conditional messages(\var{-vc}), the compiler tells you
  221. % where it encounters conditional statements.
  222. scan_c_else_found=02038_C_ELSE $1 bearbeitet, $2
  223. % When you turn on conditional messages(\var{-vc}), the compiler tells you
  224. % where it encounters conditional statements.
  225. scan_c_skipping_until=02039_C_Quelltext wird ignoriert bis...
  226. % When you turn on conditional messages(\var{-vc}), the compiler tells you
  227. % where it encounters conditional statements, and whether it is skipping or
  228. % compiling parts.
  229. scan_i_press_enter=02040_I_Dr�cken Sie <Return> um fortzusetzen
  230. % When the \var{-vi} switch is used, the compiler stops compilation
  231. % and waits for the \var{Enter} key to be pressed when it encounters
  232. % a \var{\{\$STOP\}} directive.
  233. scan_w_unsupported_switch=02041_W_Nicht unterst�tzter Schalter $1
  234. % When warings are turned on (\var{-vw}) the compiler warns you about
  235. % unsupported switches. This means that the switch is used in Delphi or
  236. % Turbo Pascal, but not in \fpc
  237. scan_w_illegal_directive=02042_W_Ung�ltiges Compilerdirektive $1
  238. % When warings are turned on (\var{-vw}) the compiler warns you about
  239. % unrecognised switches. For a list of recognised switches, \progref
  240. scan_t_back_in=02043_T_Wieder zur�ck in $1
  241. % When you use (\var{-vt}) the compiler tells you when it has finished
  242. % reading an include file.
  243. scan_w_unsupported_app_type=02044_W_Nicht unterst�tzter Anwendungstyp: $1
  244. % You get this warning, ff you specify an unknown application type
  245. % with the directive \var{\{\$APPTYPE\}}
  246. scan_w_app_type_not_support=02045_W_APPTYPE wird vom Zielbetriebssystem nicht unterst�tzt
  247. % The \var{\{\$APPTYPE\}} directive is supported by win32 applications only.
  248. scan_w_decription_not_support=02046_W_DESCRIPTION kann nur bei OS/2- und Windows-Programmen verwendet werden
  249. % The \var{\{\$DESCRIPTION\}} directive is only supported for OS2 and Win32 targets.
  250. scan_n_version_not_support=02047_N_VERSION wird vom Zielbetriebssystem nicht unterst�tzt
  251. % The \var{\{\$VERSION\}} directive is only supported by win32 target.
  252. scan_n_only_exe_version=02048_N_VERSION kann in Units nicht verwendet werden
  253. % The \var{\{\$VERSION\}} directive is only used for executable or DLL sources.
  254. scan_w_wrong_version_ignored=02049_W_Falsches Format f�r VERSION-Directive $1
  255. % The \var{\{\$VERSION\}} directive format is major_version.minor_version
  256. % where major_version and minor_version are words.
  257. scan_w_unsupported_asmmode_specifier=02050_W_Nicht unterst�tzter Assemblermodus $1 angegeben
  258. % When you specify an assembler mode with the \var{\{\$ASMMODE xxx\}}
  259. % the compiler didn't recognize the mode you specified.
  260. scan_w_no_asm_reader_switch_inside_asm=02051_W_ASM-Leser-Schalter ist innerhalb einer Asm-Sequenz nicht m”glich, $1 wird erst in der n„chsten Sequenz wirksam
  261. % It is not possible to switch from one assembler reader to another
  262. % inside an assmebler block. The new reader will be used for next
  263. % assembler statement only.
  264. scan_e_wrong_switch_toggle=02052_E_Parameter f�r Schalter falsch, verwenden Sie ON/OFF oder +/-
  265. % You need to use ON or OFF or a + or - to toggle the switch
  266. scan_e_resourcefiles_not_supported=02053_E_Resourcedateien werden vom aktuellen Zielbetriebssystem nicht unterst�tzt
  267. % The target you are compiling for doesn't support Resource files. The
  268. % only target which can use resource files is Win32
  269. scan_w_include_env_not_found=02054_W_$1 ist keine Umgebungsvariable
  270. % The included environment variable can't be found in the environment, it'll
  271. % be replaced by an empty string instead.
  272. scan_e_invalid_maxfpureg_value=02055_E_Nicht erlaubter Wert f�r MAXFPUREGISTER-Direktive
  273. % Valid values for this directive are 0..8 and NORMAL/DEFAULT
  274. % \end{description}
  275. #
  276. # Parser
  277. #
  278. % \section{Parser messages}
  279. % This section lists all parser messages. The parser takes care of the
  280. % semantics of you language, i.e. it determines if your pascal constructs
  281. % are correct.
  282. % \begin{description}
  283. scan_w_only_one_resourcefile_supported=02056_W_Nur ein Resourcedatei wird vom aktuellen Zielbetriebssystem unterst�tzt
  284. % Only one resource file can be supported for this target - this is the case of
  285. % OS/2 (EMX) currently. The first one found is used, the others are discarded.
  286. % \end{description}
  287. #
  288. # Parser
  289. #
  290. % \section{Parser messages}
  291. % This section lists all parser messages. The parser takes care of the
  292. % semantics of you language, i.e. it determines if your pascal constructs
  293. % are correct.
  294. % \begin{description}
  295. parser_e_syntax_error=03000_E_Parser - Syntaxfehler
  296. % An error against the Turbo Pascal language was encountered. This happens
  297. % typically when an illegal character is found in the sources file.
  298. parser_w_proc_far_ignored=03001_W_Schl�sselwort FAR wurde ignoriert
  299. % This is a warning. \var{FAR} is a construct for 8 or 16 bit programs. Since
  300. % the compile generates 32 bit programs, it ignores this directive.
  301. parser_w_proc_near_ignored=03002_W_Schl�sselwort NEAR wurde ignoriert
  302. % This is a warning. \var{NEAR} is a construct for 8 or 16 bit programs. Since
  303. % the compile generates 32 bit programs, it ignores this directive.
  304. parser_w_proc_interrupt_ignored=03003_W_Ignoriere Prozedurtyp INTERRUPT
  305. % This is a warning. \var{INTERRUPT} is a i386 specific construct
  306. % and is igonred for other processors.
  307. parser_e_dont_nest_interrupt=03004_E_INTERRUPT-Prozeduren d�rfen nicht verschachtelt sein
  308. % An \VAR{INTERRUPT} procedure must be global.
  309. parser_w_proc_directive_ignored=03005_W_Prozedurtyp $1 wird ignoriert
  310. % This is a warning. \var{REGISTER},\var{REINTRODUCE} is ignored by FPC programs for now.
  311. % This is introduced first for Delphi compatibility.
  312. parser_e_no_overload_for_all_procs=03006_E_Nicht alle Deklarationen von "$1" sind mit OVERLOAD deklariert
  313. % When you want to use overloading using the \var{OVERLOAD} directive, then
  314. % all declarations need to have \var{OVERLOAD} specified.
  315. parser_e_no_dll_file_specified=03007_E_Keine DLL-Datei angegeben
  316. % No longer in use.
  317. parser_e_export_name_double=03008_E_Doppelter Name f�r exportierte Funktion $1
  318. % Exported function names inside a specific DLL must all be different
  319. parser_e_export_ordinal_double=03009_E_Doppelter Index f�r exportierte Funktion $1
  320. % Exported function names inside a specific DLL must all be different
  321. parser_e_export_invalid_index=03010_E_Ung�ltiger Index for exportierte Funktion
  322. % DLL function index must be in the range \var{1..\$FFFF}
  323. parser_w_parser_reloc_no_debug=03011_W_F�r relozierbare DLL oder ausf�hrbare Datei $1 funktionieren keine Debug-Information, deaktiviert.
  324. parser_w_parser_win32_debug_needs_WN=03012_W_Um Win32-Code debuggen zu k”nnen m�ssen die Relozierungen mit -WN option abgeschaltet werden.
  325. % Stabs info is wrong for relocatable DLL or EXES use -WN
  326. % if you want to debug win32 executables.
  327. parser_e_constructorname_must_be_init=03013_E_Konstruktor-Name muss INIT sein
  328. % You are declaring a constructor with a name which isn't \var{init}, and the
  329. % \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}).
  330. parser_e_destructorname_must_be_done=03014_E_Destruktor-Name muss DONE sein
  331. % You are declaring a constructor with a name which isn't \var{done}, and the
  332. % \var{-Ss} switch is in effect. See the \var{-Ss} switch (\seeo{Ss}).
  333. parser_e_illegal_open_parameter=03015_E_Ung�ltiger Open-Parameter
  334. % You are trying to use the wrong type for an open parameter.
  335. parser_e_proc_inline_not_supported=03016_E_Schl�sselwort INLINE nicht unterst�tzt
  336. % You tried to compile a program with C++ style inlining, and forgot to
  337. % specify the \var{-Si} option (\seeo{Si}). The compiler doesn't support C++
  338. % styled inlining by default.
  339. parser_w_priv_meth_not_virtual=03017_W_Private Methoden d�rfen nicht VIRTUAL sein
  340. % You declared a method in the private part of a object (class) as
  341. % \var{virtual}. This is not allowed. Private methods cannot be overridden
  342. % anyway.
  343. parser_w_constructor_should_be_public=03018_W_Konstruktor muss PUBLIC sein
  344. % Constructors must be in the 'public' part of an object (class) declaration.
  345. parser_w_destructor_should_be_public=03019_W_Destruktor muss PUBLIC sein
  346. % Destructors must be in the 'public' part of an object (class) declaration.
  347. parser_n_only_one_destructor=03020_N_Klasse darf nur einen Destructor besitzen
  348. % You can declare only one destructor for a class.
  349. parser_e_no_local_objects=03021_E_Lokale Klassendefinitionen sind nicht zul„ssig
  350. % Classes must be defined globally. They cannot be defined inside a
  351. % procedure or function
  352. parser_f_no_anonym_objects=03022_F_Anonyme Klassendefinitionen sind nicht zul„ssig
  353. % An invalid object (class) declaration was encountered, i.e. an
  354. % object or class without methods that isn't derived from another object or
  355. % class. For example:
  356. % \begin{verbatim}
  357. % Type o = object
  358. % a : longint;
  359. % end;
  360. % \end{verbatim}
  361. % will trigger this error.
  362. parser_object_has_no_vmt=03023_E_Das Objekt $1 hat keine VMT
  363. parser_e_illegal_parameter_list=03024_E_Ung�ltige Parameterliste
  364. % You are calling a function with parameters that are of a different type than
  365. % the declared parameters of the function.
  366. parser_e_wrong_parameter_type=03025_E_Falscher Parametertyp angegeben f�r Argument Nr. $1
  367. % There is an error in the parameter list of the function or procedure.
  368. % The compiler cannot determine the error more accurate than this.
  369. parser_e_wrong_parameter_size=03026_E_Falsche Parameterzahl angegeben
  370. % There is an error in the parameter list of the function or procedure,
  371. % the number of parameters is not correct.
  372. parser_e_overloaded_no_procedure=03027_E_Bezeichner $1 ist keine Funktion, overload nicht m”glich
  373. % The compiler encountered a symbol with the same name as an overloaded
  374. % function, but it isn't a function it can overload.
  375. parser_e_overloaded_have_same_parameters=03028_E_Overload-Funktion darf nicht eine identische Parameterliste aufweisen
  376. % You're declaring overloaded functions, but with the same parameter list.
  377. % Overloaded function must have at least 1 different parameter in their
  378. % declaration.
  379. parser_e_header_dont_match_forward=03029_E_Funktionskopf ist nicht identisch mit Forward-Deklaration $1
  380. % You declared a function with same parameters but
  381. % different result type or function specifiers.
  382. parser_e_header_different_var_names=03030_E_Funktionskopf von $1 passt nicht zur Forward-Deklaration, Variablename „ndert sich: $2 => $3
  383. % You declared the function in the \var{interface} part, or with the
  384. % \var{forward} directive, but define it with a different parameter list.
  385. parser_n_duplicate_enum=03031_N_Werte in Aufz„hlungen m�ssen aufsteigend sein
  386. % \fpc allows enumeration constructions as in C. Given the following
  387. % declaration two declarations:
  388. % \begin{verbatim}
  389. % type a = (A_A,A_B,A_E:=6,A_UAS:=200);
  390. % type a = (A_A,A_B,A_E:=6,A_UAS:=4);
  391. % \end{verbatim}
  392. % The second declaration would produce an error. \var{A\_UAS} needs to have a
  393. % value higher than \var{A\_E}, i.e. at least 7.
  394. parser_n_interface_name_diff_implementation_name=03032_N_Namen in Interface und Implementation sind verschieden!
  395. % This note warns you if the implementation and interface names of a
  396. % functions are different, but they have the same mangled name. This
  397. % is important when using overloaded functions (but should produce no error).
  398. parser_e_no_with_for_variable_in_other_segments=03033_E_WITH kann nicht auf Variablen in anderen Segmenten angewendet werden
  399. % With stores a variable locally on the stack,
  400. % but this is not possible if the variable belongs to another segment.
  401. parser_e_too_much_lexlevel=03034_E_Funktionsverschachtelung gr”sser als 31
  402. % You can nest function definitions only 31 times.
  403. parser_e_range_check_error=03035_E_Bereichspr�fungsfehler bei Konstantenbestimmung
  404. % The constants are out of their allowed range.
  405. parser_w_range_check_error=03036_W_Bereichspr�fungsfehler bei Konstantenbestimmung
  406. % The constants are out of their allowed range.
  407. parser_e_double_caselabel=03037_E_doppelter CASE-Wert
  408. % You are specifying the same label 2 times in a \var{case} statement.
  409. parser_e_case_lower_less_than_upper_bound=03038_E_Obere Grenze der CASE-Bereichsangabe ist kleiner als untere Grenze
  410. % The upper bound of a \var{case} label is less than the lower bound and this
  411. % is useless
  412. parser_e_type_const_not_possible=03039_E_Klassen sind als typisierte Konstanten unzul„ssig
  413. % You cannot declare a constant of type class or object.
  414. parser_e_no_overloaded_procvars=03040_E_Funktionsvariablen von Overload-Funktionen sind unzul„ssig
  415. % You are trying to assign an overloaded function to a procedural variable.
  416. % This isn't allowed.
  417. parser_e_invalid_string_size=03041_E_Stringl„nge muss ein Wert zwischen 1 und 255 sein
  418. % The length of a string in Pascal is limited to 255 characters. You are
  419. % trying to declare a string with length lower than 1 or greater than 255
  420. % (This is not true for \var{Longstrings} and \var{AnsiStrings}.
  421. parser_w_use_extended_syntax_for_objects=03042_W_Benutzen Sie die erweiterte Syntax von NEW und DISPOSE f�r Objekt-Instanzen
  422. % If you have a pointer \var{a} to a class type, then the statement
  423. % \var{new(a)} will not initialize the class (i.e. the constructor isn't
  424. % called), although space will be allocated. you should issue the
  425. % \var{new(a,init)} statement. This will allocate space, and call the
  426. % constructor of the class.
  427. parser_w_no_new_dispose_on_void_pointers=03043_W_Verwendung von NEW oder DISPOSE mit untypisierten Pointern ist ohne Aussage
  428. parser_e_no_new_dispose_on_void_pointers=03044_E_Verwendung von NEW oder DISPOSE mit untypisierten Pointern ist nicht m”glich
  429. % You cannot use \var{new(p)} or \var{dispose(p)} if \var{p} is an untyped pointer
  430. % because no size is associated to an untyped pointer.
  431. % Accepted for compatibility in \var{tp} and \var{delphi} modes.
  432. parser_e_class_id_expected=03045_E_Klassenbezeichner erwartet
  433. % This happens when the compiler scans a procedure declaration that contains
  434. % a dot,
  435. % i.e., a object or class method, but the type in front of the dot is not
  436. % a known type.
  437. parser_e_no_type_not_allowed_here=03046_E_Typbezeichner ist hier nicht zul„ssig
  438. % You cannot use a type inside an expression.
  439. parser_e_methode_id_expected=03047_E_Methodenbezeichner erwartet
  440. % This identifier is not a method.
  441. % This happens when the compiler scans a procedure declaration that contains
  442. % a dot, i.e., a object or class method, but the procedure name is not a
  443. % procedure of this type.
  444. parser_e_header_dont_match_any_member=03048_E_Funktionskopf passt zu keiner Methode der Klasse $1
  445. % This identifier is not a method.
  446. % This happens when the compiler scans a procedure declaration that contains
  447. % a dot, i.e., a object or class method, but the procedure name is not a
  448. % procedure of this type.
  449. parser_p_procedure_start=03049_P_Prozedur/Funktion $1
  450. % When using the \var{-vp} switch, the compiler tells you when it starts
  451. % processing a procedure or function implementation.
  452. parser_e_error_in_real=03050_E_Ung�ltige Fliesskommakonstante
  453. % The compiler expects a floating point expression, and gets something else.
  454. parser_e_fail_only_in_constructor=03051_E_FAIL darf nur in Konstruktoren verwendet werden
  455. % You are using the \var{FAIL} instruction outside a constructor method.
  456. parser_e_no_paras_for_destructor=03052_E_Destruktoren k”nnen keine Parameter haben
  457. % You are declaring a destructor with a parameter list. Destructor methods
  458. % cannot have parameters.
  459. parser_e_only_class_methods_via_class_ref=03053_E_Nur Klassenmethoden k”nnen �ber den Klassennamen angesprochen werden
  460. % This error occurs in a situation like the following:
  461. % \begin{verbatim}
  462. % Type :
  463. % Tclass = Class of Tobject;
  464. %
  465. % Var C : TClass;
  466. %
  467. % begin
  468. % ...
  469. % C.free
  470. % \end{verbatim}
  471. % \var{Free} is not a class method and hence cannot be called with a class
  472. % reference.
  473. parser_e_only_class_methods=03054_E_Nur Klassenmethoden k”nnen in einer Klassenmethode angesprochen werden
  474. % This is related to the previous error. You cannot call a method of an object
  475. % from a inside a class method. The following code would produce this error:
  476. % \begin{verbatim}
  477. % class procedure tobject.x;
  478. %
  479. % begin
  480. % free
  481. % \end{verbatim}
  482. % Because free is a normal method of a class it cannot be called from a class
  483. % method.
  484. parser_e_case_mismatch=03055_E_Konstante und CASE-Typ passen nicht zueinander
  485. % One of the labels is not of the same type as the case variable.
  486. parser_e_illegal_symbol_exported=03056_E_Das Symbol kann nicht aus einer Bibliothek exportiert werden
  487. % You can only export procedures and functions when you write a library. You
  488. % cannot export variables or constants.
  489. parser_w_should_use_override=03057_W_Eine Inherit-Methode wird durch $1 verdeckt
  490. % A method that is declared \var{virtual} in a parent class, should be
  491. % overridden in the descendent class with the \var{override} directive. If you
  492. % don't specify the \var{override} directive, you will hide the parent method;
  493. % you will not override it.
  494. parser_e_nothing_to_be_overridden=03058_E_Es gibt keine Vorg„ngerklasse mit einer Methode, die damit �berschrieben werden k”nnte: $1
  495. % You try to \var{override} a virtual method of a parent class that doesn't
  496. % exist.
  497. parser_e_no_procedure_to_access_property=03059_E_Es gibt keine Member-Funktion um auf diese Property zuzugreifen
  498. % You specified no \var{read} directive for a property.
  499. parser_w_stored_not_implemented=03060_W_Die Stored Property - Direktive ist noch nicht implementiert
  500. % The \var{stored} directive is not yet implemented
  501. parser_e_ill_property_access_sym=03061_E_Ung�ltiges Symbol f�r den Zugriff auf die Property
  502. % There is an error in the \var{read} or \var{write} directives for an array
  503. % property. When you declare an array property, you can only access it with
  504. % procedures and functions. The following code woud cause such an error.
  505. % \begin{verbatim}
  506. % tmyobject = class
  507. % i : integer;
  508. % property x [i : integer]: integer read I write i;
  509. % \end{verbatim}
  510. %
  511. parser_e_cant_access_protected_member=03062_E_Kann an dieser Stelle nicht auf das gesch�tzte Feld des Objekts zugreifen
  512. % Fields that are declared in a \var{protected} section of an object or class
  513. % declaration cannot be accessed outside the module wher the object is
  514. % defined, or outside descendent object methods.
  515. parser_e_cant_access_private_member=03063_E_Kann an dieser Stelle nicht auf das private Feld des Objekts zugreifen
  516. % Fields that are declared in a \var{private} section of an object or class
  517. % declaration cannot be accessed outside the module where the class is
  518. % defined.
  519. parser_w_overloaded_are_not_both_virtual=03064_W_Overload-Methode einer virtuellen Methode muss auch virtuell sein: $1
  520. % If you declare overloaded methods in a class, then they should either all be
  521. % virtual, or none. You shouldn't mix them.
  522. parser_w_overloaded_are_not_both_non_virtual=03065_W_Overload-Methode einer nicht-virtuellen Methode muss auch nicht-virtuell sein: $1
  523. % If you declare overloaded methods in a class, then they should either all be
  524. % virtual, or none. You shouldn't mix them.
  525. parser_e_overloaded_methodes_not_same_ret=03066_E_Overload-Methoden, die virtuell sind, m�ssen den gleichen R�ckgabetyp haben: $1
  526. % If you declare virtual overloaded methods in a class definition, they must
  527. % have the same return type.
  528. parser_e_dont_nest_export=03067_E_Mit EXPORT deklarierte Funktionen d�rfen nicht verschachtelt sein
  529. % You cannot declare a function or procedure within a function or procedure
  530. % that was declared as an export procedure.
  531. parser_e_methods_dont_be_export=03068_E_Methoden d�rfen nicht EXPORTiert werden
  532. % You cannot declare a procedure that is a method for an object as
  533. % \var{export}ed. That is, your methods cannot be called from a C program.
  534. parser_e_call_by_ref_without_typeconv=03069_E_Aufrufe mit VAR-Parametern m�ssen exakt stimmen
  535. % When calling a function declared with \var{var} parameters, the variables in
  536. % the function call must be of exactly the same type. There is no automatic
  537. % type conversion.
  538. parser_e_no_super_class=03070_E_Klasse ist keine Elternklasse zur aktuellen Klasse
  539. % When calling inherited methods, you are trying to call a method of a strange
  540. % class. You can only call an inherited method of a parent class.
  541. parser_e_self_not_in_method=03071_E_SELF ist nur in Methoden erlaubt
  542. % You are trying to use the \var{self} parameter outside an object's method.
  543. % Only methods get passed the \var{self} parameters.
  544. parser_e_generic_methods_only_in_methods=03072_E_Methoden d�rfen nur in anderen Methoden direkt mit dem Klassen-Typbezeichner aufgerufen werden
  545. % A construction like \var{sometype.somemethod} is only allowed in a method.
  546. parser_e_illegal_colon_qualifier=03073_E_Unzul„ssige Verwendung von ':'
  547. % You are using the format \var{:} (colon) 2 times on an expression that
  548. % is not a real expression.
  549. parser_e_illegal_set_expr=03074_E_Bereichspr�fungsfehler im SET-Konstruktor oder doppeltes Set-Element
  550. % The declaration of a set contains an error. Either one of the elements is
  551. % outside the range of the set type, either two of the elements are in fact
  552. % the same.
  553. parser_e_pointer_to_class_expected=03075_E_Zeiger auf Objekt erwartet
  554. % You specified an illegal type in a \var{New} statement.
  555. % The extended synax of \var{New} needs an object as a parameter.
  556. parser_e_expr_have_to_be_constructor_call=03076_E_Ausdruck muss ein Konstruktor-Aufruf sein
  557. % When using the extended syntax of \var{new}, you must specify the constructor
  558. % method of the object you are trying to create. The procedure you specified
  559. % is not a constructor.
  560. parser_e_expr_have_to_be_destructor_call=03077_E_Ausdruck muss ein Destruktor-Aufruf sein
  561. % When using the extended syntax of \var{dispose}, you must specify the
  562. % destructor method of the object you are trying to dispose of.
  563. % The procedure you specified is not a destructor.
  564. parser_e_invalid_record_const=03078_E_Unzul„ssige Reihenfolge der Record-Elemente
  565. % When declaring a constant record, you specified the fields in the wrong
  566. % order.
  567. parser_e_false_with_expr=03079_E_Typ des Ausdrucks muss eine Klasse oder ein Recordtyp sein
  568. % A \var{with} statement needs an argument that is of the type \var{record}
  569. % or \var{class}. You are using \var{with} on an expression that is not of
  570. % this type.
  571. parser_e_void_function=03080_E_Prozeduren k”nnen keinen Wert zur�ckliefern
  572. % In \fpc, you can specify a return value for a function when using
  573. % the \var{exit} statement. This error occurs when you try to do this with a
  574. % procedure. Procedures cannot return a value.
  575. parser_e_constructors_always_objects=03081_E_Konstruktoren und Destruktoren m�ssen Methoden sein
  576. % You're declaring a procedure as destructor or constructor, when the
  577. % procedure isn't a class method.
  578. parser_e_operator_not_overloaded=03082_E_Operator besitzt kein Overload
  579. % You're trying to use an overloaded operator when it isn't overloaded for
  580. % this type.
  581. parser_e_no_such_assignment=03083_E_Es ist nicht m”glich, die Zuweisung f�r gleiche Typen zu �berladen
  582. % You can not overload assignment for types
  583. % that the compiler considers as equal.
  584. parser_e_overload_impossible=03084_E_Unm”gliche Operator-.berladung
  585. % The combination of operator, arguments and return type are
  586. % incompatible.
  587. parser_e_no_reraise_possible=03085_E_Ausl”sen einer Exception an dieser Stelle nicht m”glich
  588. % You are trying to raise an exception where it isn't allowed. You can only
  589. % raise exceptions in an \var{except} block.
  590. parser_e_no_new_or_dispose_for_classes=03086_E_Die erweiterte Syntax von New oder Dispose ist f�r Klassen unzul„ssig
  591. % You cannot generate an instance of a class with the extended syntax of
  592. % \var{new}. The constructor must be used for that. For the same reason, you
  593. % cannot call \var{Dispose} to de-allocate an instance of a class, the
  594. % destructor must be used for that.
  595. parser_e_asm_incomp_with_function_return=03087_E_Assembler-Funktion nicht mit diesem R�ckgabetyp m”glich
  596. % You're trying to implement a \var{assembler} function, but the return type
  597. % of the function doesn't allow that.
  598. parser_e_procedure_overloading_is_off=03088_E_Das šberladen von Prozeduren ist ausgeschaltet
  599. % When using the \var{-So} switch, procedure overloading is switched off.
  600. % Turbo Pascal does not support function overloading.
  601. parser_e_overload_operator_failed=03089_E_Es ist nicht m”glich, dieesen Operator zu �berladen (benutzen Sie stattdessen '=')
  602. % You are trying to overload an operator which cannot be overloaded.
  603. % The following operators can be overloaded :
  604. % \begin{verbatim}
  605. % +, -, *, /, =, >, <, <=, >=, is, as, in, **, :=
  606. % \end{verbatim}
  607. parser_e_comparative_operator_return_boolean=03090_E_Vergleichsoperator muss einen booleschen Wert zur�ckgeben
  608. % When overloading the \var{=} operator, the function must return a boolean
  609. % value.
  610. parser_e_only_virtual_methods_abstract=03091_E_Nur virtuelle Methoden k”nnen abstrakt sein
  611. % You are declaring a method as abstract, when it isn't declared to be
  612. % virtual.
  613. parser_f_unsupported_feature=03092_F_Benutzung einer nicht unterst�tzten Erweiterung!
  614. % You're trying to force the compiler into doing something it cannot do yet.
  615. parser_e_mix_of_classes_and_objects=03093_E_Das Mischen von Klassen und Objekten ist unzul„ssig
  616. % You cannot derive \var{objects} and \var{classes} intertwined . That is,
  617. % a class cannot have an object as parent and vice versa.
  618. parser_w_unknown_proc_directive_ignored=03094_W_Unbekannte Prozedur, Direktive $1 wurde ignoriert
  619. % The procedure direcive you secified is unknown. Recognised procedure
  620. % directives are \var{cdecl}, \var{stdcall}, \var{popstack}, \var{pascal}
  621. % \var{register}, \var{export}.
  622. parser_e_absolute_only_one_var=03095_E_ABSOLUTE kann nur auf eine alleinstehende Variable angewendet werden
  623. % You cannot specify more than one variable before the \var{absolute} directive.
  624. % Thus, the following construct will provide this error:
  625. % \begin{verbatim}
  626. % Var Z : Longint;
  627. % X,Y : Longint absolute Z;
  628. % \end{verbatim}
  629. % \begin{itemize}
  630. % \item [ absolute can only be associated a var or const ]
  631. % \end{itemize}
  632. % The address of a \var{absolute} directive can only point to a variable or
  633. % constant. Therefore, the following code will produce this error:
  634. % \begin{verbatim}
  635. % Procedure X;
  636. %
  637. % var p : longint absolute x;
  638. % \end{verbatim}
  639. %
  640. parser_e_absolute_only_to_var_or_const=03096_E_ABSOLUTE kann nur auf Variablen und Konstanten angewendet werden
  641. % The address of a \var{absolute} directive can only point to a variable or
  642. % constant. Therefore, the following code will produce this error:
  643. % \begin{verbatim}
  644. % Procedure X;
  645. %
  646. % var p : longint absolute x;
  647. % \end{verbatim}
  648. %
  649. parser_e_initialized_only_one_var=03097_E_Es kann nur EINE Variable initialisiert werden
  650. % You cannot specify more than one variable with a initial value
  651. % in Delphi syntax.
  652. parser_e_abstract_no_definition=03098_E_Abstrakte Methoden d�rfen keine Definition (mit Rumpf) haben
  653. % Abstract methods can only be declared, you cannot implement them. They
  654. % should be overridden by a descendant class.
  655. parser_e_overloaded_must_be_all_global=03099_E_Diese �berladene Funktion darf nicht lokal sein (muss Exportiert werden)
  656. % You are defining a overloaded function in the implementation part of a unit,
  657. % but there is no corresponding declaration in the interface part of the unit.
  658. parser_w_virtual_without_constructor=03100_W_Virtuelle Methoden wurden ohne Konstruktor verwendet in $1
  659. % If you declare objects or classes that contain virtual methods, you need
  660. % to have a constructor and destructor to initialize them. The compiler
  661. % encountered an object or class with virtual methods that doesn't have
  662. % a constructor/destructor pair.
  663. parser_m_macro_defined=03101_M_Makro definiert: $1
  664. % When \var{-vm} is used, the compiler tells you when it defines macros.
  665. parser_m_macro_undefined=03102_M_Makro gel”scht: $1
  666. % When \var{-vm} is used, the compiler tells you when it undefines macros.
  667. parser_m_macro_set_to=03103_M_Makro $1 auf $2 gesetzt
  668. % When \var{-vm} is used, the compiler tells you what values macros get.
  669. parser_i_compiling=03104_I_Kompiliere $1
  670. % When you turn on information messages (\var{-vi}), the compiler tells you
  671. % what units it is recompiling.
  672. parser_u_parsing_interface=03105_U_Parse Interface von Unit $1
  673. % This tells you that the reading of the interface
  674. % of the current unit starts
  675. parser_u_parsing_implementation=03106_U_Parse Implementation von $1
  676. % This tells you that the code reading of the implementation
  677. % of the current unit, library or program starts
  678. parser_d_compiling_second_time=03107_D_Kompiliere $1 zum zweiten Mal
  679. % When you request debug messages (\var{-vd}) the compiler tells you what
  680. % units it recompiles for the second time.
  681. parser_e_no_paras_allowed=03108_E_Array-Eigenschaften sind an dieser Stelle nicht erlaubt
  682. % You cannot use array properties at that point.
  683. parser_e_no_property_found_to_override=03109_E_Es gibt keine Property diesen Namens, die �berschrieben werden k”nnte
  684. % You want to overrride a property of a parent class, when there is, in fact,
  685. % no such property in the parent class.
  686. parser_e_only_one_default_property=03110_E_Es ist nur eine einzelne Default-Property erlaubt, vererbte Default-Property in Klasse $1 gefunden
  687. % You specified a property as \var{Default}, but a parent class already has a
  688. % default property, and a class can have only one default property.
  689. parser_e_property_need_paras=03111_E_Die Default-Property muss eine Array-Property sein
  690. % Only array properties of classes can be made \var{default} properties.
  691. parser_e_constructor_cannot_be_not_virtual=03112_E_Virtuelle Konstruktoren werden nur im Klassen-Objektmodell unterst�tzt
  692. % You cannot have virtual constructors in objects. You can only have them
  693. % in classes.
  694. parser_e_no_default_property_available=03113_E_Keine Default-Property verf�gbar
  695. % You try to access a default property of a class, but this class (or one of
  696. % it's ancestors) doesn't have a default property.
  697. parser_e_cant_have_published=03114_E_Die Klasse kann keinen PUBLISHED Bereich haben, benutzen Sie den {$M+} Schalter
  698. % If you want a \var{published} section in a class definition, you must
  699. % use the \var{\{\$M+\}} switch, whch turns on generation of type
  700. % information.
  701. parser_e_forward_declaration_must_be_resolved=03115_E_Forward-Deklaration der Klasse $1 muss hier aufgel”st werden, wenn sie als Elternklasse benutzt werden soll
  702. % To be able to use an object as an ancestor object, it must be defined
  703. % first. This error occurs in the following situation:
  704. % \begin{verbatim}
  705. % Type ParentClas = Class;
  706. % ChildClass = Class(ParentClass)
  707. % ...
  708. % end;
  709. % \end{verbatim}
  710. % Where \var{ParentClass} is declared but not defined.
  711. parser_e_no_local_operator=03116_E_Lokale Operatoren werden nicht unterst�tzt
  712. % You cannot overload locally, i.e. inside procedures or function
  713. % definitions.
  714. parser_e_proc_dir_not_allowed_in_interface=03117_E_Prozedur-Direktive $1 unzul„ssig im Interface-Bereich
  715. % This procedure directive is not allowed in the \var{interface} section of
  716. % a unit. You can only use it in the \var{implementation} section.
  717. parser_e_proc_dir_not_allowed_in_implementation=03118_E_Prozedur Direktive $1 unzul„ssig im Implementation-Bereich
  718. % This procedure directive is not defined in the \var{implementation} section of
  719. % a unit. You can only use it in the \var{interface} section.
  720. parser_e_proc_dir_not_allowed_in_procvar=03119_E_Prozedur-Direktive $1 unzul„ssig in einer Procvar-Deklaration
  721. % This procedure directive cannot be part of a procedural of function
  722. % type declaration.
  723. parser_e_function_already_declared_public_forward=03120_E_Funktion ist bereits als Public oder Forward deklariert: $1
  724. % You will get this error if a function is defined as \var{forward} twice.
  725. % Or it is once in the \var{interface} section, and once as a \var{forward}
  726. % declaration in the \var{implmentation} section.
  727. parser_e_not_external_and_export=03121_E_Kann nicht EXPORT und EXTERNAL gleichzeitig benutzen
  728. % These two procedure directives are mutually exclusive
  729. parser_e_name_keyword_expected=03122_E_Schl�sselwort NAME erwartet
  730. % The definition of an external variable needs a \var{name} clause.
  731. parser_w_not_supported_for_inline=03123_W_$1 noch nicht innerhalb von inline Prozeduren/Funktionen unterst�tzt
  732. % Inline procedures don't support this declaration.
  733. parser_w_inlining_disabled=03124_W_Inlining deaktiviert
  734. % Inlining of procedures is disabled.
  735. parser_i_writing_browser_log=03125_I_Schreibe Browser-Log $1
  736. % When information messages are on, the compiler warns you when it
  737. % writes the browser log (generated with the \var{\{\$Y+\}} switch).
  738. parser_h_maybe_deref_caret_missing=03126_H_M”glicherweise fehlt eine Zeiger-Dereferenzierung
  739. % The compiler thinks that a pointer may need a dereference.
  740. parser_f_assembler_reader_not_supported=03127_F_Gew„hlter Assembler-Leser nicht unterst�tzt
  741. % The selected assembler reader (with \var{\{\$ASMMODE xxx\}} is not
  742. % supported. The compiler can be compiled with or without support for a
  743. % particular assembler reader.
  744. parser_e_proc_dir_conflict=03128_E_Prozedur-Direktive $1 steht in Konflikt mit anderen Direktiven
  745. % You specified a procedure directive that conflicts with other directives.
  746. % for instance \var{cdecl} and \var{pascal} are mutually exclusive.
  747. parser_e_call_convention_dont_match_forward=03129_E_Aufrufkonvention passt nicht zur Forward-Deklaration
  748. % This error happens when you declare a function or procedure with
  749. % e.g. \var{cdecl;} but omit this directive in the implementation, or vice
  750. % versa. The calling convention is part of the function declaration, and
  751. % must be repeated in the function definition.
  752. parser_e_register_calling_not_supported=03130_E_Register-Aufrufkonvention (fastcall) nicht unterst�tzt
  753. % The \var{register} calling convention, i.e., arguments are passed in
  754. % registers instead of on the stack is not supported. Arguments are always
  755. % passed on the stack.
  756. parser_e_property_cant_have_a_default_value=03131_E_Property kann keinen Vorgabewert haben
  757. % Set properties or indexed properties cannot have a default value.
  758. parser_e_property_default_value_must_const=03132_E_Der Vorgabewert einer Property muss eine Konstante sein
  759. % The value of a \var{default} declared property must be known at compile
  760. % time. The value you specified is only known at run time. This happens
  761. % .e.g. if you specify a variable name as a default value.
  762. parser_e_cant_publish_that=03133_E_Symbol darf nicht PUBLISHED sein, dies kann nur eine Klasse sein
  763. % Only class type variables can be in a \var{published} section of a class
  764. % if they are not declared as a property.
  765. parser_e_cant_publish_that_property=03134_E_Diese Property-Art kann nicht Published sein
  766. % Properties in a \var{published} section cannot be array properties.
  767. % they must be moved to public sections. Properties in a \var{published}
  768. % section must be an ordinal type, a real type, strings or sets.
  769. parser_w_empty_import_name=03135_W_Leerer Importname angegeben
  770. % Both index and name for the import are 0 or empty
  771. parser_e_empty_import_name=03136_W_Leerer Importname angegeben
  772. % Some targets need a name for the imported procedure or a cdecl specifier
  773. parser_e_used_proc_name_changed=03137_E_Funktionsinterner Name hat sich nach der Verwendung einer Funktion ge„ndert
  774. % This is an internal error; please report any occurrences of this error
  775. % to the \fpc team.
  776. parser_e_division_by_zero=03138_E_Division durch Null
  777. % There is a divsion by zero encounted
  778. parser_e_invalid_float_operation=03139_E_Ung�ltige Fliesskomma-Operation
  779. % An operation on two real type values produced an overflow or a division
  780. % by zero.
  781. parser_e_array_lower_less_than_upper_bound=03140_E_Obere Grenze des Bereichs ist kleiner als die untere Grenze
  782. % The upper bound of a \var{case} label is less than the lower bound and this
  783. % is not possible
  784. parser_w_string_too_long=03141_W_String "$1" ist l„nger als $2
  785. % The size of the constant string is larger than the size you specified in
  786. % string type definition
  787. parser_e_string_larger_array=03142_E_Stringl„nge ist gr”sser als die L„nge des "array of char"
  788. % The size of the constant string is larger than the size you specified in
  789. % the array[x..y] of char definition
  790. parser_e_ill_msg_expr=03143_E_Ung�ltiger Ausdruck nach der 'Message'-Direktive
  791. % \fpc supports only integer or string values as message constants
  792. parser_e_ill_msg_param=03144_E_Message-Handler akzeptieren nur einen "Call by Reference" Parameter
  793. % A method declared with the \var{message}-directive as message handler
  794. % can take only one parameter which must be declared as call by reference
  795. % Parameters are declared as call by reference using the \var{var}-directive
  796. parser_e_duplicate_message_label=03145_E_Doppeltes Message-Label: $1
  797. % A label for a message is used twice in one object/class
  798. parser_e_self_in_non_message_handler=03146_E_SELF darf nur in Message-Handlern ein expliziter Parameter sein
  799. % The self parameter can be passed only explicit if it is a method which
  800. % is declared as message method handler
  801. parser_e_threadvars_only_sg=03147_E_Threadvariablen k”nnen nur statisch oder global sein
  802. % Threadvars must be static or global, you can't declare a thread
  803. % local to a procedure. Local variables are always local to a thread,
  804. % because every thread has it's own stack and local variables
  805. % are stored on the stack
  806. parser_f_direct_assembler_not_allowed=03148_F_Direkter Assembler wird f+r bin„res Ausgabeformat nicht unterst�tzt
  807. % You can't use direct assembler when using a binary writer, choose an
  808. % other outputformat or use an other assembler reader
  809. parser_w_no_objpas_use_mode=03149_W_Laden Sie die OBJPAS Unit nicht manuell, benutzen Sie statdessen {$mode objfpc} oder {$mode delphi}
  810. % You're trying to load the ObjPas unit manual from a uses clause. This is
  811. % not a good idea to do, you can better use the \var{\{\$mode objfpc\}} or
  812. % \var{\{\$mode delphi\}}
  813. % directives which load the unit automaticly
  814. parser_e_no_object_override=03150_E_OVERRIDE darf in Objekten nicht verwendet werden
  815. % Override isn't support for objects, use VIRTUAL instead to override
  816. % a method of an anchestor object
  817. parser_e_cant_use_inittable_here=03151_E_Datentypen, die ein Initialiserung oder Finalisierung ben”tigen, k”nnen in varianten Records nicht verwendet werden
  818. % Some data type (e.g. \var{ansistring}) needs initialization/finalization
  819. % code which is implicitly generated by the compiler. Such data types
  820. % can't be used in the variant part of a record.
  821. parser_e_resourcestring_only_sg=03152_E_Resourcestrings d�rfen nur statisch oder global sein
  822. % Resourcestring can not be declared local, only global or using the static
  823. % directive.
  824. parser_e_exit_with_argument_not__possible=03153_E_EXIT mit Argument darf hier nicht verwendet werden
  825. % an exit statement with an argument for the return value can't be used here, this
  826. % can happen e.g. in \var{try..except} or \var{try..finally} blocks
  827. parser_e_stored_property_must_be_boolean=03154_E_Der Typ des STORED-Symbols muss boolesch sein
  828. % If you specify a storage symbol in a property declaration, it must be of
  829. % the type boolean
  830. parser_e_ill_property_storage_sym=03155_E_Dieses Symbol ist als Speichersymbol unzul„ssig
  831. % You can't use this type of symbol as storage specifier in property
  832. % declaration. You can use only methods with the result type boolean,
  833. % boolean class fields or boolean constants
  834. parser_e_only_publishable_classes_can__be_published=03156_E_Nur Klassen, die im "$M+"-Modus kompiliert wurden, d�rfen published sein
  835. % In the published section of a class can be only class as fields used which
  836. % are compiled in $M+ or which are derived from such a class. Normally
  837. % such a class should be derived from TPersitent
  838. parser_e_proc_directive_expected=03157_E_Prozedurdirektive erwartet
  839. % When declaring a procedure in a const block you used a ; after the
  840. % procedure declaration after which a procedure directive must follow.
  841. % Correct declarations are:
  842. % \begin{verbatim}
  843. % const
  844. % p : procedure;stdcall=nil;
  845. % p : procedure stdcall=nil;
  846. % \end{verbatim}
  847. parser_e_invalid_property_index_value=03158_E_Der Wert f�r einen Property-Index muss ordinalen Typs sein
  848. % The value you use to index a property must be of an ordinal type, for
  849. % example an integer or enumerated type.
  850. parser_e_procname_to_short_for_export=03159_E_Prozedurname zu kurz um exportiert zu werden
  851. % The length of the procedure/function name must be at least 2 characters
  852. % long. This is because of a bug in dlltool which doesn't parse the .def
  853. % file correct with a name of length 1.
  854. parser_e_dlltool_unit_var_problem=03160_E_Es kann kein DEFFILE-Eintrag f�r unit-globale Variablen erzeugt werden
  855. parser_e_dlltool_unit_var_problem2=03161_E_Kompiliere ohne "-WD"-Option
  856. #
  857. # Type Checking
  858. #
  859. % \section{Type checking errors}
  860. % This section lists all errors that can occur when type checking is
  861. % performed.
  862. % \begin{description}
  863. type_e_mismatch=04000_E_Typen passen nicht zusammen
  864. % This can happen in many cases:
  865. % \begin{itemize}
  866. % \item The variable you're assigning to is of a different type than the
  867. % expression in the assignment.
  868. % \item You are calling a function or procedure with parameters that are
  869. % incompatible with the parameters in the function or procedure definition.
  870. % \end{itemize}
  871. type_e_incompatible_types=04001_E_Inkompatible Typen: Habe "$1" erhalten, aber "$2" erwartet
  872. % There is no conversion possible between the two types
  873. % Another possiblity is that they are declared in different
  874. % declarations:
  875. % \begin{verbatim}
  876. % Var
  877. % A1 : Array[1..10] Of Integer;
  878. % A2 : Array[1..10] Of Integer;
  879. %
  880. % Begin
  881. % A1:=A2; { This statement gives also this error, it
  882. % is due the strict type checking of pascal }
  883. % End.
  884. % \end{verbatim}
  885. type_e_not_equal_types=04002_E_Typen sind verschieden bei $1 und $2
  886. % The types are not equal
  887. type_e_type_id_expected=04003_E_Typbezeichner erwartet
  888. % The identifier is not a type, or you forgot to supply a type identifier.
  889. type_e_variable_id_expected=04004_E_Variablenbezeichner erwartet
  890. % This happens when you pass a constant to a \var{Inc} var or \var{Dec}
  891. % procedure. You can only pass variables as arguments to these functions.
  892. type_e_integer_expr_expected=04005_E_Integer-Ausdruck erwartet, aber "$1" erhalten
  893. % The compiler expects an expression of type integer, but gets a different
  894. % type.
  895. type_e_boolean_expr_expected=04006_E_Booleschen Ausdruck erwartet, aber "$1" erhalten
  896. % The expression must be a boolean type, it should be return true or
  897. % false.
  898. type_e_ordinal_expr_expected=04007_E_Ganzahligen Ausdruck erwartet
  899. % The expression must be of ordinal type, i.e., maximum a \var{Longint}.
  900. % This happens, for instance, when you specify a second argument
  901. % to \var{Inc} or \var{Dec} that doesn't evaluate to an ordinal value.
  902. type_e_pointer_type_expected=04008_E_Zeigertyp erwartet, aber "$1" erhalten
  903. % The variable or expression isn't of the type \var{pointer}. This
  904. % happens when you pass a variable that isn't a pointer to \var{New}
  905. % or \var{Dispose}.
  906. type_e_class_type_expected=04009_E_Klassentyp erwartet, aber "$1" erhalten
  907. % The variable of expression isn't of the type \var{class}. This happens
  908. % typically when
  909. % \begin{enumerate}
  910. % \item The parent class in a class declaration isn't a class.
  911. % \item An exception handler (\var{On}) contains a type identifier that
  912. % isn't a class.
  913. % \end{enumerate}
  914. type_e_varid_or_typeid_expected=04010_E_Variable oder Typbezeichner erwartet
  915. % The argument to the \var{High} or \var{Low} function is not a variable
  916. % nor a type identifier.
  917. type_e_cant_eval_constant_expr=04011_E_Kann konstanten Ausdruck nicht auswerten
  918. % No longer in use.
  919. type_e_set_element_are_not_comp=04012_E_Set-Elemente sind nicht kompatibel
  920. % You are trying to make an operation on two sets, when the set element types
  921. % are not the same. The base type of a set must be the same when taking the
  922. % union
  923. type_e_set_operation_unknown=04013_E_Operation f�r Sets nicht implementiert
  924. % several binary operations are not defined for sets
  925. % like div mod ** (also >= <= for now)
  926. type_w_convert_real_2_comp=04014_W_Automatische Typumwandlung von Fliesskommatyp nach COMP (=integer mit 64 bit)
  927. % An implicit type conversion from a real type to a \var{comp} is
  928. % encountered. Since \var{Comp} is a 64 bit integer type, this may indicate
  929. % an error.
  930. type_h_use_div_for_int=04015_H_Verwenden sie DIV um ein Integer-Ergebnis zu erhalten
  931. % When hints are on, then an integer division with the '/' operator will
  932. % procuce this message, because the result will then be of type real
  933. type_e_strict_var_string_violation=04016_E_Stringtypen passen nicht zueinander, da in "$V+"-Modus
  934. % When compiling in \var{\{\$V+\}} mode, the string you pass as a parameter
  935. % should be of the exact same type as the declared parameter of the procedure.
  936. type_e_succ_and_pred_enums_with_assign_not_possible=04017_E_Succ oder Pred kann nicht auf Aufz„hlungen mit Zuweisungen angewendet werden
  937. % When you declared an enumeration type which has assignments in it, as in C,
  938. % like in the following:
  939. % \begin{verbatim}
  940. % Tenum = (a,b,e:=5);
  941. % \end{verbatim}
  942. % you cannot use the \var{Succ} or \var{Pred} functions on them.
  943. type_e_cant_read_write_type=04018_E_Kann Variablen dieses Typs nicht lesen oder schreiben
  944. % You are trying to \var{read} or \var{write} a variable from or to a
  945. % file of type text, which doesn't support that. Only integer types,
  946. % booleans, reals, pchars and strings can be read from/written to a text file.
  947. type_e_no_readln_writeln_for_typed_file=04019_E_Kann ReadLn und WriteLn nicht bei typisierten Dateien verwenden
  948. % \var{readln} and \var{writeln} are only allowed for text files.
  949. type_e_no_read_write_for_untyped_file=04020_E_Kann Read und Write nicht bei untypisierten Dateien verwenden
  950. % \var{read} and \var{write} are only allowed for text or typed files.
  951. type_e_typeconflict_in_set=04021_E_Typkonflikt zwischen den Elementen des Sets
  952. % There is at least one set element which is of the wrong type, i.e. not of
  953. % the set type.
  954. type_w_maybe_wrong_hi_lo=04022_W_lo/hi(dword/qword) gibt oberes/unteres Word/DWord zur�ck
  955. % \fpc supports an overloaded version of \var{lo/hi} for \var{longint/dword/int64/qword}
  956. % which returns the lower/upper word of the argument. TP always uses
  957. % a 16 bit \var{lo/hi} which returns always bits 0..7 for \var{lo} and the
  958. % bits 8..15 for \var{hi}. If you want the TP behavior you have
  959. % to type case the argument to \var{word/integer}
  960. type_e_integer_or_real_expr_expected=04023_E_Integer- oder Real-Ausdruck erwartet
  961. % The first argument to \var{str} must a real or integer type.
  962. type_e_wrong_type_in_array_constructor=04024_E_Falscher Typ im Array-Konstructor
  963. % You are trying to use a type in an array constructor which is not
  964. % allowed.
  965. type_e_wrong_parameter_type=04025_E_Inkompatible Typen f�r Argument Nr. #$1: habe $2 erhalten, aber $3 erwartet
  966. % You are trying to pass an invalid type for the specified parameter.
  967. type_e_no_method_and_procedure_not_compatible=04026_E_Methode (Variable) und Prozedur (Variable) sind nicht kompatibel
  968. % You can't assign a method to a procedure variable or a procedure to a
  969. % method pointer.
  970. type_e_wrong_math_argument=04027_E_Unzul„ssige Konstante an interne Algebrafunktion �bergeben
  971. % The constant argument passed to a ln or sqrt function is out of
  972. % the definition range of these functions.
  973. type_e_no_addr_of_constant=04028_E_Von Konstanten kann keine Adresse bestimmt werden
  974. % It's not possible to get the address of a constant, because they
  975. % aren't stored in memory, you can try making it a typed constant.
  976. type_e_argument_cant_be_assigned=04029_E_Auf das Argument kann nichts zugewiesen werden
  977. % Only expressions which can be on the left side of an
  978. % assignment can be passed as call by reference argument
  979. % Remark: Properties can be only
  980. % used on the left side of an assignment, but they can't be used as arguments
  981. type_e_cannot_local_proc_to_procvar=04030_E_Kann lokale Prozedur/Funktion nicht an Prozedurvariable zuweisen
  982. % It's not allowed to assign a local procedure/function to a
  983. % procedure variable, because the calling of local procedure/function is
  984. % different. You can only assign local procedure/function to a void pointer.
  985. type_e_no_assign_to_addr=04031_E_Kann einer Adresse keine Werte zuweisen
  986. % It's not allowed to assign a value to an address of a variable,constant,
  987. % procedure or function. You can try compiling with -So if the identifier
  988. % is a procedure variable.
  989. type_e_no_assign_to_const=04032_E_Kann einer Konstanten keine Werte zuweisen
  990. % It's not allowed to assign a value to a variable which is declared
  991. % as a const. This is normally a parameter declared as const, to allow
  992. % changing make the parameter value or var.
  993. % \end{description}
  994. #
  995. # Symtable
  996. #
  997. % \section{Symbol handling}
  998. % This section lists all the messages that concern the handling of symbols.
  999. % This means all things that have to do with procedure and variable names.
  1000. % \begin{description}
  1001. sym_e_id_not_found=05000_E_Bezeichner "$1" nicht gefunden
  1002. % The compiler doesn't know this symbol. Usually happens when you misspel
  1003. % the name of a variable or procedure, or when you forgot to declare a
  1004. % variable.
  1005. sym_f_internal_error_in_symtablestack=05001_F_Interner Fehler in SymTableStack()
  1006. % An internal error occurred in the compiler; If you encounter such an error,
  1007. % please contact the developers and try to provide an exact description of
  1008. % the circumstances in which the error occurs.
  1009. sym_e_duplicate_id=05002_E_Doppelter Bezeichner "$1"
  1010. % The identifier was already declared in the current scope.
  1011. sym_h_duplicate_id_where=05003_H_Bezeichner ist bereits definiert in $1 in Zeile $2
  1012. % The identifier was already declared in a previous scope.
  1013. sym_e_unknown_id=05004_E_Unbekannter Bezeichner "$1"
  1014. % The identifier encountered hasn't been declared, or is used outside the
  1015. % scope where it's defined.
  1016. sym_e_forward_not_resolved=05005_E_Forward-Deklaration "$1" nicht gefunden
  1017. % This can happen in two cases:
  1018. % \begin{itemize}
  1019. % \item This happens when you declare a function (in the \var{interface} part, or
  1020. % with a \var{forward} directive, but do not implement it.
  1021. % \item You reference a type which isn't declared in the current \var{type}
  1022. % block.
  1023. % \end{itemize}
  1024. sym_f_id_already_typed=05006_F_Bezeichnertyp ist bereits als Typ definiert
  1025. % You are trying to redefine a type.
  1026. sym_e_error_in_type_def=05007_E_Fehler in Typdefinition
  1027. % There is an error in your definition of a new array type:
  1028. % \item One of the range delimiters in an array declaration is erroneous.
  1029. % For example, \var{Array [1..1.25]} will trigger this error.
  1030. sym_e_type_id_not_defined=05008_E_Typbezeichner nicht definiert
  1031. % The type identifier has not been defined yet.
  1032. sym_e_forward_type_not_resolved=05009_E_Forward-Typ "$1" nicht gefunden
  1033. % The compiler encountered an unknown type.
  1034. sym_e_only_static_in_static=05010_E_Nur statische Variablen k”nnen in statischen oder „usseren Methoden verwendet werden
  1035. % A static method of an object can only access static variables.
  1036. sym_e_invalid_call_tvarsymmangledname=05011_E_Ung�ltiger Aufruf von tvarsym.mangledname()
  1037. % An internal error occurred in the compiler; If you encounter such an error,
  1038. % please contact the developers and try to provide an exact description of
  1039. % the circumstances in which the error occurs.
  1040. sym_f_type_must_be_rec_or_class=05012_F_Record- oder Klassen-Typ erwartet
  1041. % The variable or expression isn't of the type \var{record} or \var{class}.
  1042. sym_e_no_instance_of_abstract_object=05013_E_Instanzen von Klassen oder Objekten mit abstrakten Methoden sind unzul„ssig
  1043. % You are trying to generate an instance of a class which has an abstract
  1044. % method that wasn't overridden.
  1045. sym_w_label_not_defined=05014_W_Label "$1" nicht definiert
  1046. % A label was declared, but not defined.
  1047. sym_e_label_used_and_not_defined=05015_E_Label "$1" benutzt aber nicht definiert
  1048. % A label was declared and used, but not defined.
  1049. sym_e_ill_label_decl=05016_E_Ung�ltige Label-Deklaration
  1050. % This error should never happen; it occurs if a label is defined outside a
  1051. % procedure or function.
  1052. sym_e_goto_and_label_not_supported=05017_E_GOTO und LABEL werden nicht unterst�tzt (verwenden Sie den Schalter -Sg)
  1053. % You must compile a program which has \var{label}s and \var{goto} statements
  1054. % with the \var{-Sg} switch. By default, \var{label} and \var{goto} aren't
  1055. % supported.
  1056. sym_e_label_not_found=05018_E_Label nicht gefunden
  1057. % A \var{goto label} was encountered, but the label isn't declared.
  1058. sym_e_id_is_no_label_id=05019_E_Bezeichner ist kein Label
  1059. % The identifier specified after the \var{goto} isn't of type label.
  1060. sym_e_label_already_defined=05020_E_Label ist bereits definiert
  1061. % You are defining a label twice. You can define a label only once.
  1062. sym_e_ill_type_decl_set=05021_E_Ung�ltige Typdeklaration von Set-Elementen
  1063. % The declaration of a set contains an invalid type definition.
  1064. sym_e_class_forward_not_resolved=05022_E_Forward-Klassendefinition nicht gefunden: $1
  1065. % You declared a class, but you didn't implement it.
  1066. sym_n_unit_not_used=05023_H_Unit "$1" wird von "$2" nicht verwendet
  1067. % The unit referenced in the \var{uses} clause is not used.
  1068. sym_h_para_identifier_not_used=05024_H_Parameter nicht verwendet: $1
  1069. % This is a warning. The identifier was declared (locally or globally) but
  1070. % wasn't used (locally or globally).
  1071. sym_n_local_identifier_not_used=05025_N_Lokale Variable nicht verwendet: $1
  1072. % You have declared, but not used a variable in a procedure or function
  1073. % implementation.
  1074. sym_h_para_identifier_only_set=05026_H_Werte-Parameter "$1" wurde zugewiesen aber nie verwendet
  1075. % This is a warning. The identifier was declared (locally or globally)
  1076. % set but not used (locally or globally).
  1077. sym_n_local_identifier_only_set=05027_N_Lokale Variable "$1" wurde zugewiesen aber nicht verwendet
  1078. % The variable in a procedure or function
  1079. % implementation is declared, set but never used.
  1080. sym_h_local_symbol_not_used=05028_H_Lokales $1-Element "$2" wird nicht verwendet
  1081. % A local symbol is never used.
  1082. sym_n_private_identifier_not_used=05029_N_Privates Feld $1.$2 wird nie verwendet
  1083. sym_n_private_identifier_only_set=05030_N_Privates Feld $1.$2 wurde zugewiesen aber nie verwendet
  1084. sym_n_private_method_not_used=05031_N_Private Methode $1.$2 wird nie verwendet
  1085. sym_e_set_expected=05032_E_Mengentyp erwartet
  1086. % The variable or expression isn't of type \var{set}. This happens in an
  1087. % \var{in} statement.
  1088. sym_w_function_result_not_set=05033_W_Funktionsergebnis scheint nicht gesetzt zu sein
  1089. % You can get this warning if the compiler thinks that a function return
  1090. % value is not set. This will not be displayed for assembler procedures,
  1091. % or procedures that contain assembler blocks.
  1092. sym_w_wrong_C_pack=05034_W_Typ "$1" ist im aktuellen Record mit C-Packing nicht korrekt ausgerichtet
  1093. % Arrays with sizes not multiples of 4 will be wrongly aligned
  1094. % for C structures.
  1095. sym_e_illegal_field=05035_E_Unbekannter Record-Feldbezeichner $1
  1096. % The field doesn't exist in the record definition.
  1097. sym_n_uninitialized_local_variable=05036_W_Lokale Variable "$1" wird verwendet, bevor ihr ein Wert zugewiesen wurde
  1098. sym_n_uninitialized_variable=05037_W_Variable "$1" scheint nicht initialisert worden zu sein
  1099. % These messages are displayed if the compiler thinks that a variable will
  1100. % be used (i.e. appears in the right-hand-side of an expression) when it
  1101. % wasn't initialized first (i.e. appeared in the left-hand side of an
  1102. % assigment)
  1103. sym_e_id_no_member=05038_E_Bezeichener verweist nicht auf ein Element: $1
  1104. % When using the extended syntax of \var{new}, you must specify the constructor
  1105. % method of the class you are trying to create. The procedure you specified
  1106. % does not exist.
  1107. sym_b_param_list=05039_B_Deklaration gefunden: $1
  1108. % You get this when you use the \var{-vb} switch. In case an overloaded
  1109. % procedure is not found, then all candidate overloaded procedures are
  1110. % listed, with their parameter lists.
  1111. sym_e_segment_too_large=05040_E_Datensegment zu gross (max. 2GB)
  1112. % You get this when you declare an array whose size exceeds the 2GB limit.
  1113. % \end{description}
  1114. #
  1115. # Codegenerator
  1116. #
  1117. % \section{Code generator messages}
  1118. % This section lists all messages that can be displayed if the code
  1119. % generator encounters an error condition.
  1120. % \begin{description}
  1121. cg_e_break_not_allowed=06000_E_BREAK nicht zul„ssig
  1122. % You're trying to use \var{break} outside a loop construction.
  1123. cg_e_continue_not_allowed=06001_E_CONTINUE nicht zul„ssig
  1124. % You're trying to use \var{continue} outside a loop construction.
  1125. cg_e_too_complex_expr=06002_E_Ausdruck zu komplex - FPU Stack�berlauf
  1126. % Your expression is too long for the compiler. You should try dividing the
  1127. % construct over multiple assignments.
  1128. cg_e_illegal_expression=06003_E_Ung�ltiger Ausdruck
  1129. % This can occur under many circumstances. Mostly when trying to evaluate
  1130. % constant expressions.
  1131. cg_e_invalid_integer=06004_E_Ung�ltiger Ausdruck, kein Integer
  1132. % You made an expression which isn't an integer, and the compiler expects the
  1133. % result to be an integer.
  1134. cg_e_invalid_qualifier=06005_E_Ung�ltige Kombination
  1135. % One of the following is happening :
  1136. % \begin{itemize}
  1137. % \item You're trying to access a field of a variable that is not a record.
  1138. % \item You're indexing a variable that is not an array.
  1139. % \item You're dereferencing a variable that is not a pointer.
  1140. % \end{itemize}
  1141. cg_e_upper_lower_than_lower=06006_E_Oberes Bereichsende < unteres Bereichsende
  1142. % You are declaring a subrange, and the lower limit is higher than the high
  1143. % limit of the range.
  1144. cg_e_illegal_count_var=06007_E_Unzul„ssige Z„hlvariable
  1145. % The type of a \var{for} loop variable must be an ordinal type.
  1146. % Loop variables cannot be reals or strings.
  1147. cg_e_cant_choose_overload_function=06008_E_Kann mich bestimmen, welche �berladene Funktion aufgerufen werden soll
  1148. % You're calling overloaded functions with a parameter that doesn't correspond
  1149. % to any of the declared function parameter lists. e.g. when you have declared
  1150. % a function with parameters \var{word} and \var{longint}, and then you call
  1151. % it with a parameter which is of type \var{integer}.
  1152. cg_e_parasize_too_big=06009_E_Gr”sse der Parameterliste �bersteigt 65535 Bytes
  1153. % The I386 processor limits the parameter list to 65535 bytes (the \var{RET}
  1154. % instruction causes this)
  1155. cg_e_illegal_type_conversion=06010_E_Unzul„ssige Typumwandlung
  1156. % When doing a type-cast, you must take care that the sizes of the variable and
  1157. % the destination type are the same.
  1158. cg_d_pointer_to_longint_conv_not_portable=06011_D_Umwandlung zwischen ganzen Zahlen und Pointern ist zwischen verschiedenen Plattformen nicht portabel
  1159. % If you typecast a pointer to a longint, this code will not compile
  1160. % on a machine using 64bit for pointer storage.
  1161. cg_e_file_must_call_by_reference=06012_E_Dateitypen m�ssen VAR Parameter sein
  1162. % You cannot specify files as value parameters, i.e. they must always be
  1163. % declared \var{var} parameters.
  1164. cg_e_cant_use_far_pointer_there=06013_E_Die Verwendung eines FAR-Zeigers ist in dieser Art nicht erlaubt
  1165. % Free Pascal doesn't support far pointers, so you cannot take the address of
  1166. % an expression which has a far reference as a result. The \var{mem} construct
  1167. % has a far reference as a result, so the following code will produce this
  1168. % error:
  1169. % \begin{verbatim}
  1170. % var p : pointer;
  1171. % ...
  1172. % p:=@mem[a000:000];
  1173. % \end{verbatim}
  1174. cg_e_var_must_be_reference=06014_E_Unzul„ssiger "call by reference"-Parameter
  1175. % You are trying to pass a constant or an expression to a procedure that
  1176. % requires a \var{var} parameter. Only variables can be passed as a \var{var}
  1177. % parameter.
  1178. cg_e_dont_call_exported_direct=06015_E_Mit EXPORT deklarierte Funktionen k”nnen nicht aufgerufen werden
  1179. % No longer in use.
  1180. cg_w_member_cd_call_from_method=06016_W_M”glicherweise unzul„ssiger Aufruf eines Konstruktors oder Destruktors (passt nicht in diesen Kontext)
  1181. % No longer in use.
  1182. cg_n_inefficient_code=06017_N_Uneffiziente Programmierung
  1183. % You construction seems dubious to the compiler.
  1184. cg_w_unreachable_code=06018_W_Code wird niemals ausgef�hrt
  1185. % You specified a loop which will never be executed. Example:
  1186. % \begin{verbatim}
  1187. % while false do
  1188. % begin
  1189. % {.. code ...}
  1190. % end;
  1191. % \end{verbatim}
  1192. cg_e_stackframe_with_esp=06019_E_Prozeduraufruf mit Stackframe ESP/SP
  1193. % The compiler enocountered a procedure or function call inside a
  1194. % procedure that uses a \var{ESP/SP} stackframe. Normally, when a call is
  1195. % done the procedure needs a \var{EBP} stackframe.
  1196. cg_e_cant_call_abstract_method=06020_E_Abstrakte Methoden k”nnen nicht direkt aufgerufen werden
  1197. % You cannot call an abstract method directy, instead you must call a
  1198. % overriding child method, because an abstract method isn't implemented.
  1199. cg_f_internal_error_in_getfloatreg=06021_F_Interner Fehler in getfloatreg(), Allozierungsfehler
  1200. % An internal error occurred in the compiler; If you encounter such an error,
  1201. % please contact the developers and try to provide an exact description of
  1202. % the circumstances in which the error occurs.
  1203. cg_f_unknown_float_type=06022_F_Unbekannter Fliesskommatyp
  1204. % The compiler cannot determine the kind of float that occurs in an expression.
  1205. cg_f_secondvecn_base_defined_twice=06023_F_SecondVecn() Basis wurde zweimal definiert
  1206. % An internal error occurred in the compiler; If you encounter such an error,
  1207. % please contact the developers and try to provide an exact description of
  1208. % the circumstances in which the error occurs.
  1209. cg_f_extended_cg68k_not_supported=06024_F_Extended wird auf der m68k-Plattform nicht unterst�tzt
  1210. % The var{extended} type is not supported on the m68k platform.
  1211. cg_f_32bit_not_supported_in_68000=06025_F_Vorzeichenlose 32-Bit-Typen werden im MC68000-Modus nicht unterst�zt
  1212. % The cardinal/dword is not supported on the m68k platform.
  1213. cg_f_internal_error_in_secondinline=06026_F_Interner Fehler in secondinline()
  1214. % An internal error occurred in the compiler; If you encounter such an error,
  1215. % please contact the developers and try to provide an exact description of
  1216. % the circumstances in which the error occurs.
  1217. cg_d_register_weight=06027_D_Register $1 Gewichtung $2 $3
  1218. % Debugging message. Shown when the compiler considers a variable for
  1219. % keeping in the registers.
  1220. cg_e_stacklimit_in_local_routine=06028_E_Stacklimit in lokaler Routine �berschritten
  1221. % Your code requires a too big stack. Some operating systems pose limits
  1222. % on the stack size. You should use less variables or try ro put large
  1223. % variables on the heap.
  1224. cg_d_stackframe_omited=06029_D_Stackframe wird ausgelassen
  1225. % Some procedure/functions do not need a complete stack-frame, so it is omitted.
  1226. % This message will be displayed when the {-vd} switch is used.
  1227. cg_w_64bit_range_check_not_supported=06030_W_Bereichs�berpr�fung f�r 64-Bit-Integer wird f�r die Zielplattform nicht unterst�tzt
  1228. % 64 bit range check is not yet implemented for 32 bit processors.
  1229. cg_e_unable_inline_object_methods=06031_E_Objektmethoden k”nnen nicht Inline sein
  1230. % You cannot have inlined object methods.
  1231. cg_e_unable_inline_procvar=06032_E_Procvar-Aufrufe k”nnen nicht Inline sein
  1232. % A procedure with a procedural variable call cannot be inlined.
  1233. cg_e_no_code_for_inline_stored=06033_E_Kein Code f�r Inline-Prozedur gespeichert
  1234. % The compiler couldn't store code for the inline procedure.
  1235. cg_e_no_call_to_interrupt=06034_E_Direkter Aufruf von Interruptprozedur $1 ist nicht m”glich
  1236. % You can not call an interrupt procedure directly from FPC code
  1237. cg_e_can_access_element_zero=06035_E_Auf Element Null von Ansi/Wide- oder Longstring kann nicht zugegriffen werden, benutzen Sie stattdessen (Set)Length
  1238. % You should use \var{setlength} to set the length of an ansi/wide/longstring
  1239. % and \var{length} to get the length of such kinf of string
  1240. cg_e_include_not_implemented=06036_E_Include und Exclude sind f�r diesen Fall noch nicht implementiert
  1241. % \var{include} and \var{exclude} are only partially
  1242. % implemented for \var{i386} processors
  1243. % and not at all for \var{m68k} processors.
  1244. cg_e_cannot_call_cons_dest_inside_with=06037_E_Konstruktoren und Destruktoren k”nnen in diesem Kontext nicht aufgerufen werden
  1245. % Inside a \var{With} clause you cannot call a constructor or destructor for the
  1246. % object you have in the \var{with} clause.
  1247. cg_e_cannot_call_message_direct=06038_E_Kann Messagehandler-Methode nicht direkt aufrufen
  1248. % A message method handler method can't be called directly if it contains an
  1249. % explicit self argument
  1250. % \end{description}
  1251. # EndOfTeX
  1252. #
  1253. # Assembler reader
  1254. #
  1255. cg_e_goto_inout_of_exception_block=06039_E_Sprung in- oder aus Exceptionblock heraus
  1256. % It isn't allowed to jump in or outside of an exception block like \var{try..finally..end;}:
  1257. % \begin{verbatim}
  1258. % label 1;
  1259. %
  1260. % ...
  1261. %
  1262. % try
  1263. % if not(final) then
  1264. % goto 1; // this line will cause an error
  1265. % finally
  1266. % ...
  1267. % end;
  1268. % 1:
  1269. % ...
  1270. % \end{verbatim}
  1271. % \end{description}
  1272. # EndOfTeX
  1273. cg_e_control_flow_outside_finally=06040_E_Kontrollfluss-Anweisungen sind in einem Finally-Block nicht erlaubt
  1274. % It isn't allowed to use the control flow statements \var{break},
  1275. % \var{continue} and \var{exit}
  1276. % inside a finally statement. The following example shows the problem:
  1277. % \begin{verbatim}
  1278. % ...
  1279. % try
  1280. % p;
  1281. % finally
  1282. % ...
  1283. % exit; // This exit ISN'T allowed
  1284. % end;
  1285. % ...
  1286. %
  1287. % \end{verbatim}
  1288. % If the procedure \var{p} raises an exception the finally block is
  1289. % executed. If the execution reaches the exit, it's unclear what to do:
  1290. % exiting the procedure or searching for another exception handler
  1291. # EndOfTeX
  1292. #
  1293. # Assembler reader
  1294. #
  1295. asmr_d_start_reading=07000_D_Starte $1 Stil Assembler Parsen
  1296. % This informs you that an assembler block is being parsed
  1297. asmr_d_finish_reading=07001_D_Beende $1 Stil Assembler Parsen
  1298. % This informs you that an assembler block has finished.
  1299. asmr_e_none_label_contain_at=07002_E_Nicht-Label Bezeichner enth„lt @
  1300. % A identifier which isn't a label can't contain a @.
  1301. asmr_w_override_op_not_supported=07003_W_Override-Operator wird nicht unterst�tzt
  1302. % The Override operator is not supported
  1303. asmr_e_building_record_offset=07004_E_Fehler beim Ermitteln des Recordoffsets
  1304. % There has an error occured while building the offset of a record/object
  1305. % structure, this can happend when there is no field specified at all or
  1306. % an unknown field identifier is used.
  1307. asmr_e_offset_without_identifier=07005_E_OFFSET ohne Bezeicner verwendet
  1308. % You can only use OFFSET with an identifier. Other syntaxes aren't
  1309. % supported
  1310. asmr_e_type_without_identifier=07006_E_TYPE verwendet ohne Bezeichner
  1311. % You can only use TYPE with an identifier. Other syntaxes aren't
  1312. % supported
  1313. asmr_e_no_local_or_para_allowed=07007_E_Lokale Variable oder Parameter k”nnen hier nicht verwendet werden
  1314. % You can't use a local variable or parameter here, mostly because the
  1315. % addressing of locals and parameters is done using the %ebp register so the
  1316. % address can't be get directly.
  1317. asmr_e_need_offset=07008_E_Hier muss OFFSET verwendet werden
  1318. % You need to use OFFSET <id> here to get the address of the identifier.
  1319. asmr_e_need_dollar=07009_E_Hier muss "$" verwendet werden
  1320. % You need to use $<id> here to get the address of the identifier.
  1321. asmr_e_cant_have_multiple_relocatable_symbols=07010_E_Verwendung von mehreren verschiebbaren Symbolen nicht m”glich
  1322. % You can't have more than one relocatable symbol (variable/typed constant)
  1323. % in one argument.
  1324. asmr_e_only_add_relocatable_symbol=07011_E_Verschiebbares Symbol kann nur addiert werden
  1325. % Relocatable symbols (variable/typed constant) can't be used with other
  1326. % operators. Only addition is allowed.
  1327. asmr_e_invalid_constant_expression=07012_E_Ung�ltiger Konstantenausdruck
  1328. % There is an error in the constant expression.
  1329. asmr_e_relocatable_symbol_not_allowed=07013_E_Verschiebbares Symbol ist nicht zul„ssig
  1330. % You can't use a relocatable symbol (variable/typed constant) here.
  1331. asmr_e_invalid_reference_syntax=07014_E_Ung�ltige Verweis-Syntax
  1332. % There is an error in the reference.
  1333. asmr_e_local_para_unreachable=07015_E_Sie k”nnen "$1" von diesem Code aus nicht erreichen
  1334. % You can not read directly the value of local or para
  1335. % of a higher level in assembler code (except for
  1336. % local assembler code without parameter nor locals).
  1337. asmr_e_local_label_not_allowed_as_ref=07016_E_Lokale Symbole/Labels sind nicht als Referenz zul„ssig
  1338. % You can't use local symbols/labels as references
  1339. asmr_e_wrong_base_index=07017_E_Ung�ltige Verwendung von Basis- und Index-Registern
  1340. % There is an error with the base and index register
  1341. asmr_w_possible_object_field_bug=07018_W_M”glicher Fehler bei Objektfeld-Behandlung
  1342. % Fields of objects or classes can be reached directly in normal or objfpc
  1343. % modes but TP and Delphi modes treat the field name as a simple offset.
  1344. asmr_e_wrong_scale_factor=07019_E_Falscher Skalierungsfaktor angegeben
  1345. % The scale factor given is wrong, only 1,2,4 and 8 are allowed
  1346. asmr_e_multiple_index=07020_E_Mehrfache Verwendung fon Index-Registern
  1347. % You are trying to use more than one index register
  1348. asmr_e_invalid_operand_type=07021_E_Ung�ltiger Operandentyp
  1349. % The operand type doesn't match with the opcode used
  1350. asmr_e_invalid_string_as_opcode_operand=07022_E_Ung�litge Zeichenkette als Opcode-Operand: $1
  1351. % The string specified as operand is not correct with this opcode
  1352. asmr_w_CODE_and_DATA_not_supported=07023_W_@CODE und @DATA werden nicht unterst�tzt
  1353. % @CODE and @DATA are unsupported and are ignored.
  1354. asmr_e_null_label_ref_not_allowed=07024_E_Null-Label-Bezug nicht m”glich
  1355. asmr_e_expr_zero_divide=07025_E_Division durch Null in Assembler-Ausdruck
  1356. asmr_e_expr_illegal=07026_E_Ung�ltiger Ausdruck
  1357. asmr_e_escape_seq_ignored=07027_E_Escape-Sequenz ignoriert: $1
  1358. asmr_e_invalid_symbol_ref=07028_E_Ung�ltige Symbolverwendung
  1359. asmr_w_fwait_emu_prob=07029_W_FWAIT kann Emulationsprobleme mit emu387 verursachen
  1360. asmr_w_fadd_to_faddp=07030_W_FADD ohne Operand wurde in FADDP�bersetzt
  1361. asmr_w_enter_not_supported_by_linux=07031_W_Der ENTER-Befehl wird vom Linux-Kernel nicht unterst�tzt
  1362. % ENTER instruction can generate a stack page fault that is not
  1363. % caught correctly by the i386 Linux page handler.
  1364. asmr_w_calling_overload_func=07032_W_Aufruf einer �berladenen Funktion in Assembler
  1365. asmr_e_unsupported_symbol_type=07033_E_Nicht unterst�tzter Symboltyp f�r Operand
  1366. asmr_e_constant_out_of_bounds=07034_E_Wert der Konstante ausserhalb des zul„ssigen Bereichs
  1367. asmr_e_error_converting_decimal=07035_E_Fehler beim Umwandeln in Dezimal $1
  1368. asmr_e_error_converting_octal=07036_E_Fehler beim Umwandeln in Oktal $1
  1369. asmr_e_error_converting_binary=07037_E_Fehler beim Umwandeln in Bin„r $1
  1370. asmr_e_error_converting_hexadecimal=07038_E_Fehler beim Umwandeln in Hexadezimal $1
  1371. asmr_h_direct_global_to_mangled=07039_H_$1 �bersetzt nach $2
  1372. asmr_w_direct_global_is_overloaded_func=07040_W_$1 ist einer �berladenen Funktion zugeordnet
  1373. asmr_e_cannot_use_SELF_outside_a_method=07041_E_Kann SELF nicht ausserhalb einer Methode verwenden
  1374. asmr_e_cannot_use_OLDEBP_outside_nested_procedure=07042_E_Kann OLDEBP ausserhalb einer verschachtelten Prozedur nicht verwenden
  1375. asmr_e_void_function=07043_W_Prozeduren k”nnen keinen Wert im Assembler-Code zur�ckliefern
  1376. asmr_e_SEG_not_supported=07044_E_SEG nicht unterst�tzt
  1377. asmr_e_size_suffix_and_dest_dont_match=07045_E_Gr”ssensuffix und Ziel- oder Quellgr”sse passen nicht zusammen
  1378. asmr_w_size_suffix_and_dest_dont_match=07046_W_Gr”ssensuffix und Ziel- oder Quellgr”sse passen nicht zusammen
  1379. asmr_e_syntax_error=07047_E_Assembler Syntaxfehler
  1380. asmr_e_invalid_opcode_and_operand=07048_E_Ung�ltige Kombination von Opcode und Operanden
  1381. asmr_e_syn_operand=07049_E_Assembler Syntaxfehler im Operanden
  1382. asmr_e_syn_constant=07050_E_Assembler Syntaxfehler in Konstanten
  1383. asmr_e_invalid_string_expression=07051_E_Ung�ltiger Stringausdruck
  1384. asmr_w_const32bit_for_address=07052_-Bit-Konstanten f�r Adresse erzeugt
  1385. asmr_e_unknown_opcode=07053_E_Unbekannter Opcode $1
  1386. asmr_e_invalid_or_missing_opcode=07054_E_Ung�ltiger oder fehlender Opcode
  1387. asmr_e_invalid_prefix_and_opcode=07055_E_Ung�ltige Kombination von Prefix und Opcode: $1
  1388. asmr_e_invalid_override_and_opcode=07056_E_Ung�ltige Kombination von Override und Opcode: $1
  1389. asmr_e_too_many_operands=07057_E_Zu viele Operanden in der Zeile
  1390. asmr_w_near_ignored=07058_W_NEAR ignoriert
  1391. asmr_w_far_ignored=07059_W_FAR ignoriert
  1392. asmr_e_dup_local_sym=07060_E_Doppelters lokales Symbol $1
  1393. asmr_e_unknown_local_sym=07061_E_Undefiniertes lokales Symbol $1
  1394. asmr_e_unknown_label_identifier=07062_E_Unbekannter Label-Bezeichner $1
  1395. asmr_e_invalid_register=07063_E_Ung�ltiger Registername
  1396. asmr_e_invalid_fpu_register=07064_E_Ung�ltiger Name f�r Fliesskommaregister
  1397. asmr_e_nor_not_supported=07065_E_NOR nicht unterst�tzt
  1398. asmr_w_modulo_not_supported=07066_W_Modulo nicht unterst�tzt
  1399. asmr_e_invalid_float_const=07067_E_Ung�ltige Fliesskommakonstante $1
  1400. asmr_e_invalid_float_expr=07068_E_Ung�ltiger Fliesskommaausdruck
  1401. asmr_e_wrong_sym_type=07069_E_Falscher Symboltyp
  1402. asmr_e_cannot_index_relative_var=07070_E_Kann lokale Variable oder Parameter nicht mit Register indizieren
  1403. asmr_e_invalid_seg_override=07071_E_Ung�ltiger Segmentoverride-Ausdruck
  1404. asmr_w_id_supposed_external=07072_W_Bezeichner $1 ist vermutlich External
  1405. asmr_e_string_not_allowed_as_const=07073_E_Strings sind als Konstanten unzul„ssig
  1406. asmr_e_no_var_type_specified=07074_Typ der Variablen nicht angegeben
  1407. asmr_w_assembler_code_not_returned_to_text=07075_E_Assemblercode kehrt nicht zum Text zur�ck
  1408. asmr_e_not_directive_or_local_symbol=07076_E_Keine Direktive oder lokales Symbol $1
  1409. asmr_w_using_defined_as_local=07077_E_Verwendung eines definierten Namens als lokales Label
  1410. asmr_e_dollar_without_identifier=07078_E_Dollarzeichen wird ohne Bezeichner verwendet
  1411. asmr_w_32bit_const_for_address=07079_W_32-Bit-Konstante f�r Adresse erzeugt
  1412. asmr_n_align_is_target_specific=07080_N_.align ist abh„ngig von Zielplattform, verwende .balign oder .p2align
  1413. asmr_e_cannot_access_field_directly_for_parameters=07081_E_Kann f�r Parameter nicht direkt auf Felder zugreifen
  1414. % You should load the parameter first into a register and then access the
  1415. % fields using that register.
  1416. asmr_e_cannot_access_object_field_directly=07082_E_Kann auf Felder von Objekten/Klassen nicht direkt zugreifen
  1417. % You should load the self pointer first into a register and then access the
  1418. % fields using the register as base. By default the self pointer is available
  1419. % in the esi register on i386.
  1420. #
  1421. # Assembler/binary writers
  1422. #
  1423. asmw_f_too_many_asm_files=08000_F_Zu viele Assembler-Dateien
  1424. asmw_f_assembler_output_not_supported=08001_F_Gew„hlte Assemblerausgabe wird nicht unterst�tzt
  1425. asmw_f_comp_not_supported=08002_F_Comp nicht unterst�tzt
  1426. asmw_f_direct_not_supported=08003_F_Direct nicht unterst�tzt f�r bin„res Schreiben
  1427. asmw_e_alloc_data_only_in_bss=08004_E_Allozieren von Daten ist nur in "bss"-Abschnitten zul„ssig
  1428. asmw_f_no_binary_writer_selected=08005_F_Kein Bin„rschreiber ausgew„hlt
  1429. asmw_e_opcode_not_in_table=08006_E_Asm: Opcode $1 nicht in Tabelle enthalten
  1430. asmw_e_invalid_opcode_and_operands=08007_E_Asm: $1 ung�ltige Kombination von Opcode und Operanden
  1431. asmw_e_16bit_not_supported=08008_E_Asm: 16-Bit-Verweise werden nicht untert�tzt
  1432. asmw_e_invalid_effective_address=08009_E_Asm: Ung�ltige effektive Adresse
  1433. asmw_e_immediate_or_reference_expected=08010_E_Asm: Konstanten Ausdruck oder Referenz erwartet
  1434. asmw_e_value_exceeds_bounds=08011_E_Asm: $1 Wert �berschreitet Grenzen $2
  1435. asmw_e_short_jmp_out_of_range=08012_E_Asm: "Short jump" ist ausserhalb der Bereichs $1
  1436. asmw_e_undefined_label=08013_E_Asm: Undefiniertes Label: $1
  1437. #
  1438. # Executing linker/assembler
  1439. #
  1440. exec_w_source_os_redefined=09000_W_Quell-Betriebssystem wurde neu definiert
  1441. exec_i_assembling_pipe=09001_I_Assembliere (pipe) $1
  1442. exec_d_cant_create_asmfile=09002_E_Kann Assemblerdatei nicht erzeugen: $1
  1443. % The mentioned file can't be create. Check if you've
  1444. % permission to create this file
  1445. exec_e_cant_create_objectfile=09003_E_Kann Objektdatei nicht erzeugen: $1
  1446. % The mentioned file can't be create. Check if you've
  1447. % permission to create this file
  1448. exec_e_cant_create_archivefile=09004_E_Kann Archivdatei nicht erzeugen: $1
  1449. % The mentioned file can't be create. Check if you've
  1450. % permission to create this file
  1451. exec_w_assembler_not_found=09005_W_Assembler $1 nicht gefunden, schalte um auf externes Assemblieren
  1452. exec_t_using_assembler=09006_T_Benutze Assembler: $1
  1453. exec_w_error_while_assembling=09007_W_Fehler w„hren des Assemblierens, Exitcode $1
  1454. exec_w_cant_call_assembler=09008_W_Kann den Assembler nicht aufrufen, Fehler $1 beim Umschalten auf externen Assembler
  1455. exec_i_assembling=09009_I_Assembliere $1
  1456. exec_i_assembling_smart=09010_I_Assembliere mit Smartlinking $1
  1457. exec_w_objfile_not_found=09011_W_Objekt $1 nicht gefunden, Linken kann fehlschlagen!
  1458. exec_w_libfile_not_found=09012_W_Bibliothek $1 nicht gefunden, Linken kann fehlschlagen!
  1459. exec_w_error_while_linking=09013_W_Fehler w„hrend des Linkens
  1460. exec_w_cant_call_linker=09014_W_Kann Linker nicht aufrufen, schalte um auf externes Linken
  1461. exec_i_linking=09015_I_Linke $1
  1462. exec_w_util_not_found=09016_W_Hilfsprogramm "$1" nicht gefunden, schalte um auf externes Linken
  1463. exec_t_using_util=09017_T_Benutze Hilfsprogramm $1
  1464. exec_e_exe_not_supported=09018_E_Erzeugen von ausf�hrbaren Dateien nicht unterst�tzt
  1465. exec_e_dll_not_supported=09019_E_Dynamische Bibliotheken nicht unterst�tzt
  1466. exec_i_closing_script=09020_I_Schliesse Skript $1
  1467. exec_w_res_not_found=09021_W_Resource Compiler nicht gefunden, schalte um auf externen Modus
  1468. exec_i_compilingresource=09022_I_Kompiliere Resource $1
  1469. #
  1470. # Executable information
  1471. #
  1472. execinfo_f_cant_process_executable=09023_F_Kann ausf�hrbare Datei nicht nachbearbeiten: $1
  1473. execinfo_f_cant_open_executable=09024_F_Kann ausf�hrbare Datei nicht ”ffnen: $1
  1474. execinfo_x_codesize=09025_X_Gr”sse des Codes: $1 Bytes
  1475. execinfo_x_initdatasize=09026_X_Gr”sse der initialisierten Daten: $1 Bytes
  1476. execinfo_x_uninitdatasize=09027_X_Gr”sse der nicht initialisierten Daten: $1 Bytes
  1477. execinfo_x_stackreserve=09028_X_Stack Bereich "reserved": $1 Bytes
  1478. execinfo_x_stackcommit=09029_X_Stack Bereich "commited": $1 Bytes
  1479. #
  1480. # Unit loading
  1481. #
  1482. # BeginOfTeX
  1483. % \section{Unit loading messages.}
  1484. % This section lists all messages that can occur when the compiler is
  1485. % loading a unit from disk into memory. Many of these mesages are
  1486. % informational messages.
  1487. % \begin{description}
  1488. unit_t_unitsearch=10000_T_Suche Unit: $1
  1489. % When you use the \var{-vt}, the compiler tells you where it tries to find
  1490. % unit files.
  1491. unit_t_ppu_loading=10001_T_Lade PPU: $1
  1492. % When the \var{-vt} switch is used, the compiler tells you
  1493. % what units it loads.
  1494. unit_u_ppu_name=10002_U_PPU-Name: $1
  1495. % When you use the \var{-vu} flag, the unit name is shown.
  1496. unit_u_ppu_flags=10003_U_PPU-Flags: $1
  1497. % When you use the \var{-vu} flag, the unit flags are shown.
  1498. unit_u_ppu_crc=10004_U_PPU-CRC: $1
  1499. % When you use the \var{-vu} flag, the unit CRC check is shown.
  1500. unit_u_ppu_time=10005_U_PPU-Zeit: $1
  1501. % When you use the \var{-vu} flag, the unit time is shown.
  1502. unit_u_ppu_file_too_short=10006_U_PPU-Datei zu kurz
  1503. % When you use the \var{-vu} flag, the unit time is shown.
  1504. unit_u_ppu_invalid_header=10007_U_PPU Ung�ltiger Header (kein PPU am Anfang)
  1505. % A unit file contains as the first three bytes the ascii codes of \var{PPU}
  1506. unit_u_ppu_invalid_version=10008_U_PPU Ung�ltige Version $1
  1507. % This unit file was compiled with a different version of the compiler, and
  1508. % cannot be read.
  1509. unit_u_ppu_invalid_processor=10009_U_PPU ist f�r einen anderen Prozessor kompiliert
  1510. % This unit file was compiled for a different processor type, and
  1511. % cannot be read
  1512. unit_u_ppu_invalid_target=10010_U_PPU ist f�r ein anderes Zielsystem kompiliert
  1513. % This unit file was compiled for a different processor type, and
  1514. % cannot be read
  1515. unit_u_ppu_source=10011_U_PPU Quelle: $1
  1516. % When you use the \var{-vu} flag, the unit CRC check is shown.
  1517. unit_u_ppu_write=10012_U_Schreibe $1
  1518. % When you specify the \var{-vu} switch, the compiler will tell you where it
  1519. % writes the unit file.
  1520. unit_f_ppu_cannot_write=10013_F_Kann PPU-Datei nicht schreiben
  1521. % An err
  1522. unit_f_ppu_read_error=10014_F_Lese PPU-Datei
  1523. % Unexpected end of file
  1524. unit_f_ppu_read_unexpected_end=10015_F_Unerwartetes Ende der PPU-Datei
  1525. % This means that the unit file was corrupted, and contains invalid
  1526. % information. Recompilation will be necessary.
  1527. unit_f_ppu_invalid_entry=10016_F_Ung�ltiger Eintrag in PPU-Datei: $1
  1528. % The unit the compiler is trying to read is corrupted, or generated with a
  1529. % newer version of the compiler.
  1530. unit_f_ppu_dbx_count_problem=10017_F_PPU Dbx Z„hler-Problem
  1531. % There is an inconsistency in the debugging information of the unit.
  1532. unit_e_illegal_unit_name=10018_E_Ung�ltiger Unitname: $1
  1533. % The name of the unit doesn't match the file name.
  1534. unit_f_too_much_units=10019_F_Zu viele Units
  1535. % \fpc has a limit of 1024 units in a program. You can change this behavior
  1536. % by changing the \var{maxunits} constant in the \file{files.pas} file of the
  1537. % compiler, and recompiling the compiler.
  1538. unit_f_circular_unit_reference=10020_F_Gegenseitige Abh„ngigkeit von Units zwischen $1 und $2
  1539. % Two units are using each other in the interface part. This is only allowed
  1540. % in the \var{implementation} part. At least one unit must contain the other one
  1541. % in the \var{implementation} section.
  1542. unit_f_cant_compile_unit=10021_F_Kann Unit "$1" nicht �bersetzen, keine Quellen vorhanden
  1543. % A unit was found that needs to be recompiled, but no sources are
  1544. % available.
  1545. unit_f_cant_find_ppu=10022_F_Kann Unit "$1" nicht finden
  1546. % You tried to use a unit of which the PPU file isn't found by the
  1547. % compiler. Check your config files for the unit pathes
  1548. unit_w_unit_name_error=10023_W_Unit "$1" wurde nicht gefunden, aber "$2" existiert
  1549. unit_f_unit_name_error=10024_F_Unit "$1" gesucht, aber "$2" gefunden
  1550. % Dos truncation of 8 letters for unit PPU files
  1551. % may lead to problems when unit name is longer than 8 letters.
  1552. unit_w_switch_us_missed=10025_W_šbersetzen der Systemunit erfordert den Schalter -Us
  1553. % When recompiling the system unit (it needs special treatment), the
  1554. % \var{-Us} must be specified.
  1555. unit_f_errors_in_unit=10026_F_Es traten $1 Fehler beim šbersetzen des Moduls auf, halte an
  1556. % When the compiler encounters a fatal error or too many errors in a module
  1557. % then it stops with this message.
  1558. unit_u_load_unit=10027_U_Lade aus $1 ($2) die Unit $3
  1559. % When you use the \var{-vu} flag, which unit is loaded from which unit is
  1560. % shown.
  1561. unit_u_recompile_crc_change=10028_U_šbersetze $1 erneut, Pr�fsumme f�r $2 hat sich ge„ndert
  1562. unit_u_recompile_source_found_alone=10029_U_šbersetze "$1", nur Quellcode gefunden
  1563. % When you use the \var{-vu} flag, these messages tell you why the current
  1564. % unit is recompiled.
  1565. unit_u_recompile_staticlib_is_older=10030_U_šbersetze Unit erneut, statische Biblothek ist „lter als PPU-Datei
  1566. % When you use the \var{-vu} flag, the compiler warns if the static library
  1567. % of the unit are older than the unit file itself.
  1568. unit_u_recompile_sharedlib_is_older=10031_U_šbersetze Unit erneut, gemeinsame Bibliothek ist „lter als PPU-Datei
  1569. % When you use the \var{-vu} flag, the compiler warns if the shared library
  1570. % of the unit are older than the unit file itself.
  1571. unit_u_recompile_obj_and_asm_older=10032_U_šbersetze Unit erneut, obj und asm sind „lter als PPU-Datei
  1572. % When you use the \var{-vu} flag, the compiler warns if the assembler of
  1573. % object file of the unit are older than the unit file itself.
  1574. unit_u_recompile_obj_older_than_asm=10033_U_šbersetze Unit erneut, obj ist „lter als asm
  1575. % When you use the \var{-vu} flag, the compiler warns if the assembler
  1576. % file of the unit is older than the object file of the unit.
  1577. unit_u_start_parse_interface=10034_U_Parse Interface-Abschnitt von "$1"
  1578. % When you use the \var{-vu} flag, the compiler warns that it starts
  1579. % parsing the interface part of the unit
  1580. unit_u_start_parse_implementation=10035_U_Parse Implementation-Abschnitt von "$1"
  1581. % When you use the \var{-vu} flag, the compiler warns that it starts
  1582. % parsing the implementation part of the unit
  1583. unit_u_second_load_unit=10036_U_Zweites Laden f�r Unit "$1"
  1584. % When you use the \var{-vu} flag, the compiler warns that it starts
  1585. % recompiling a unit for the second time. This can happend with interdepend
  1586. % units.
  1587. unit_u_check_time=10037_U_PPU pr�fe Datei $1 Zeit $2
  1588. % When you use the \var{-vu} flag, the compiler show the filename and
  1589. % date and time of the file which a recompile depends on
  1590. % \end{description}
  1591. # EndOfTeX
  1592. #
  1593. # Options
  1594. #
  1595. option_usage=11000_$1 [Optionen] <Eingabedatei> [Optionen]
  1596. # BeginOfTeX
  1597. %
  1598. % \section{Command-line handling errors}
  1599. % This section lists errors that occur when the compiler is processing the
  1600. % command line or handling the configuration files.
  1601. % \begin{description}
  1602. option_only_one_source_support=11001_W_Nur eine Quelldatei unterst�tzt
  1603. % You can specify only one source file on the command line. The first
  1604. % one will be compiled, others will be ignored. This may indicate that
  1605. % you forgot a \var{'-'} sign.
  1606. option_def_only_for_os2=11002_W_DEF-Datei kann nur f�r OS/2 erzeugt werden
  1607. % This option can only be specified when you're compiling for OS/2
  1608. option_no_nested_response_file=11003_E_Verschachtelte Response-Dateien werden nicht unterst�tzt
  1609. % you cannot nest response files with the \var{@file} command-line option.
  1610. option_no_source_found=11004_F_Kein Name f�r Quelldatei auf der Kommandzeile
  1611. % The compiler expects a source file name on the command line.
  1612. option_no_option_found=11005_N_Keine Angeben in Konfigurationsdatei "$1" gefunden
  1613. % The compiler didn't find any option in that config file.
  1614. option_illegal_para=11006_E_Ung�ltiger Parameter: $1
  1615. % You specified an unknown option.
  1616. option_help_pages_para=11007_H_-? zeigt Hilfetext an
  1617. % When an unknown option is given, this message is diplayed.
  1618. option_too_many_cfg_files=11008_F_Zu viele verschachtelte Konfigurtionsdateien
  1619. % You can only nest up to 16 config files.
  1620. option_unable_open_file=11009_F_Kann Datei nicht ”ffnen $1
  1621. % The option file cannot be found.
  1622. option_reading_further_from=11010_N_Lese weitere Optionen aus $1
  1623. % Displayed when you have notes turned on, and the compiler switches
  1624. % to another options file.
  1625. option_target_is_already_set=11011_W_Zielsystem ist bereits gesetzt: $1
  1626. % Displayed if more than one \var{-T} option is specified.
  1627. option_no_shared_lib_under_dos=11012_W_Gemeinsame Bibliotheken sind auf der DOS Platform nicht verf�gbar, verwende stattdessen statische Bibliotheken
  1628. % If you specify \var{-CD} for the \dos platform, this message is displayed.
  1629. % The compiler supports only static libraries under \dos
  1630. option_too_many_ifdef=11013_F_Zu viele IF(N)DEFs
  1631. % the \var{\#IF(N)DEF} statements in the options file are not balanced with
  1632. % the \var{\#ENDIF} statements.
  1633. option_too_many_endif=11014_F_Zu viele ENDIFs
  1634. % the \var{\#IF(N)DEF} statements in the options file are not balanced with
  1635. % the \var{\#ENDIF} statements.
  1636. option_too_less_endif=11015_F_Offene Bedingung am Dateiende
  1637. % the \var{\#IF(N)DEF} statements in the options file are not balanced with
  1638. % the \var{\#ENDIF} statements.
  1639. option_no_debug_support=11016_W_Erzeugung von Debug-Informationen wird von dieser ausf�hrbaren Datei nicht unterst�tzt
  1640. % It is possible to have a compiler executable that doesn't support
  1641. % the generation of debugging info. If you use such an executable with the
  1642. % \var{-g} switch, this warning will be displayed.
  1643. option_no_debug_support_recompile_fpc=11017_H_Versuchen Sie mit -dGDB erneut zu kompilieren
  1644. % It is possible to have a compiler executable that doesn't support
  1645. % the generation of debugging info. If you use such an executable with the
  1646. % \var{-g} switch, this warning will be displayed.
  1647. option_obsolete_switch=11018_E_Sie verwenden den nun �berfl�ssigen Schalter $1
  1648. % this warns you when you use a switch that is not needed/supported anymore.
  1649. % It is recommended that you remove the switch to overcome problems in the
  1650. % future, when the switch meaning may change.
  1651. option_obsolete_switch_use_new=11019_E_Sie benutzen den nun �berfl�ssigen Schalter $1, bitte benutzen Sie $2
  1652. % this warns you when you use a switch that is not supported anymore. You
  1653. % must now use the second switch instead.
  1654. % It is recommended that you change the switch to overcome problems in the
  1655. % future, when the switch meaning may change.
  1656. option_switch_bin_to_src_assembler=11020_N_Schalte Assembler auf den Standard-Assembler-Quellcodeschreiber
  1657. % this notifies you that the assembler has been changed because you used the
  1658. % -a switch which can't be used with a binary assembler writer.
  1659. option_incompatible_asm=11021_W_Das gew„hlte Assembler-Ausgabeformat "$1" ist nicht mit "$2" kompatibel
  1660. option_asm_forced=11022_W_Verwendung des Assemblers "$1" erzwungen
  1661. % The assembler output selected can not generate
  1662. % object files with the correct format. Therefore, the
  1663. % default assembler for this target is used instead.
  1664. %\end{description}
  1665. # EndOfTeX
  1666. #
  1667. # Logo (option -l)
  1668. #
  1669. option_logo=11023_[
  1670. Free Pascal Compiler Version $FPCVER [$FPCDATE] f�r $FPCTARGET
  1671. Copyright (c) 1993-2002 Florian Kl„mpfl
  1672. ]
  1673. #
  1674. # Info (option -i)
  1675. #
  1676. option_info=11024_[
  1677. Free Pascal Compiler Version $FPCVER
  1678. Compiler Datum: $FPCDATE
  1679. Compiler Zielsystem: $FPCTARGET
  1680. Dieses Programm unterliegt der GNU General Public Licence
  1681. Weitere Informationen sind in COPYING.FPC zu finden
  1682. Fehlerberichte, Vorschl„ge usw. bitte senden an:
  1683. [email protected]
  1684. ]
  1685. #
  1686. # Help pages (option -? and -h)
  1687. #
  1688. option_help_pages=11025_[
  1689. **0*_nach booleschen Optionen geben Sie + zum Ein- bzw. - zum Ausschalten an
  1690. **1a_l”sche die erzeugte Assembler-Datei nicht
  1691. **2al_liste Quellcode-Zeilen in der Assembler-Datei
  1692. **2ar_liste Registerbelegungsinformation in Assembler-Datei
  1693. **2at_liste Temp. Variablenbelegungsinfo in Assembler-Datei
  1694. **1b_erzeuge Browser-Info
  1695. **2bl_erzeuge Info zu lokalen Symbolen
  1696. **1B_erzeuge alle Module (Build)
  1697. **1C<x>_Optionen f�r Code-Erzeugung:
  1698. 3*2CD_erzeuge auch eine dynamische Bibliothek (nicht unterst�tzt)
  1699. **2Ch<n>_<n> Bytes Heap (zwischen 1023 und 67107840)
  1700. **2Ci_I/O-Pr�fung
  1701. **2Cn_lasse die Linkstufe aus
  1702. **2Co_pr�fe šberlauf von Integer-Operationen
  1703. **2Cr_f�hre Bereichspr�fung durch
  1704. **2Cs<n>_setze Gr”sse des Stacks auf <n>
  1705. **2Ct_f�hre Stackpr�fung durch
  1706. 3*2CS_erzeuge statische Bibliothek
  1707. 3*2Cx_benutze Smartlinking
  1708. **1d<x>_definiere das Symbol <x>
  1709. *O1D_erzeuge eine DEF-Datei
  1710. *O2Dd<x>_setze Beschreibung zu <x>
  1711. *O2Dw_erzeuge PM-Anwendung
  1712. **1e<x>_setze Pfad zur ausf�hrbaren Datei
  1713. **1F<x>_Dateinamen und Pfade:
  1714. **2FD<x>_setze das Verzeichnis f�r die Compiler-Hilfsprogramme
  1715. **2Fe<x>_leite die Fehlerausgabe um nach <x>
  1716. **2FE<x>_setze den Pfad f�r Exe/Unit-Dateien auf <x>
  1717. *L2Fg<x>_identisch mit -Fl
  1718. **2Fi<x>_erg„nze <x> zum Include-Pfad
  1719. **2Fl<x>_erg„nze <x> zum Bibliotheks-Pfad
  1720. *L2FL<x>_benutze <x> als dynamischen Linker
  1721. **2Fo<x>_erg„nze <x> zum Objektdatei-Pfad
  1722. **2Fr<x>_lade die Fehler-Meldungs Datei <x>
  1723. **2Fu<x>_erg„nze <x> zum Unit-Pfad
  1724. **2FU<x>_Units werden nach <x> ausgegen, hat Vorrang vor -FE
  1725. *g1g<x>_erzeuge Informationen zur Fehlersuche:
  1726. *g2gg_Verwende gsym
  1727. *g2gd_Verwende dbx
  1728. *g2gh_Heaptrace-Unit einbinden
  1729. *g2gc_Zeiger�berpr�fung
  1730. **1i_zeige alle Information �ber den Compiler
  1731. **2iD_zeige Compilerdatum
  1732. **2iV_zeige Compilerversion
  1733. **2iSO_zeige Compiler-Betriebssystem
  1734. **2iSP_zeige Compilerprozessor
  1735. **2iTO_zeige Ziel-Betriebssystem
  1736. **2iTP_zeige Zielprozessor
  1737. **1I<x>_erg„nze <x> zum Include-Pfad
  1738. **1k<x>_�bergebe <x> an den Linker
  1739. **1l_zeige Logo
  1740. **1n_Standard-Konfigurationsdatei ignorieren
  1741. **1o<x>_die erzeugte, ausf�hrbaren Datei bekommt den Namen <x>
  1742. **1pg_erzeuge Profiler-Code f�r gprof
  1743. *L1P_benutze Pipes anstelle von tempor„ren Assembler-Dateien
  1744. **1S<x>_Syntax-Optionen:
  1745. **2S2_schalte einige der Delphi 2 Erweiterungen ein
  1746. **2Sc_unterst�tze spezielle C Operatoren (*=,+=,/= and -=)
  1747. **2Sd_sei Delphi-kompatibel
  1748. **2Se_halte Compiler nach dem ersten Fehler an
  1749. **2Sg_erlaube LABEL und GOTO
  1750. **2Sh_benutze ANSI-Strings
  1751. **2Si_benutze C++ artige INLINE
  1752. **2Sm_unterst�tze Makros wie in C (global)
  1753. **2So_sei TP/BP 7.0 kompatibel
  1754. **2Sp_sei gpc-kompatibel
  1755. **2Ss_Kon-und Destruktorname m�ssen "Init" und "Done" sein
  1756. **2St_erlaube Schl�sselwort static in Objekten
  1757. **1s_rufe weder Assembler noch Linker auf (nur mit -a)
  1758. **1u<x>_entferne die Definition f�r das Symbol <x>
  1759. **1U<x>_Unit-Optionen:
  1760. **2Un_pr�fe den Unitnamen nicht
  1761. **2Us_erzeuge eine Systemunit
  1762. **1v<x>_Meldungen, <x> ist eine Kombination der folgenden Zeichen:
  1763. **2*_e : Fehler (Standard) d : Debug Info
  1764. **2*_w : Warnungen u : Unit Info
  1765. **2*_n : Anmerkungen t : angesprochene/benutzte Dateien
  1766. **2*_h : Hinweise m : definierte Macros
  1767. **2*_i : allgemeine Info p : kompilierte Prozeduren
  1768. **2*_l : Zeilennummern c : Preprozessordirective
  1769. **2*_a : alles 0 : nichts (ausser Fehlern)
  1770. **2*_b : alle Prozedurdekla- r : Rhide/GCC kompatibler Modus
  1771. **2*_ rationen im Fehlerfall x : Exe-Datei Info (nur Win32)
  1772. **2*_
  1773. **1X<x>_Optionen f�r ausf�hrbare Dateien:
  1774. *L2Xc_linke mit der C-Bibliothek
  1775. **2Xs_entferne alle Symbole von ausf�hrbarer Datei
  1776. **2XD_dynamisch linken (definiert FPC_LINK_DYNAMIC)
  1777. **2XS_statisch linken (default) (definiert FPC_LINK_STATIC)
  1778. **2XX_smartlinken (definiert FPC_LINK_SMART)
  1779. **0*_Optionen f�r den Prozessor:
  1780. 3*1A<x>_Ausgabeformat:
  1781. 3*2Aas_Datei mit Hilfe von GNU AS
  1782. 3*2Aasaout_Datei mit Hilfe von GNU AS f�r aout (Go32v1)
  1783. 3*2Anasmcoff_coff-Datei mit Hilfe von Nasm
  1784. 3*2Anasmelf_elf32-Datei (Linux) mit Hilfe von Nasm
  1785. 3*2Anasmobj_obj-Datei mit Hilfe von Nasm
  1786. 3*2Amasm_obj-Datei mit Hilfe von Masm (Microsoft)
  1787. 3*2Atasm_obj-Datei mit Hilfe von Tasm (Borland)
  1788. 3*2Acoff_coff (Go32v2) benutze internen Schreiber
  1789. 3*2Apecoff_pecoff (Win32) benutze internen Schreiber
  1790. 3*1R<x>_Assembler-Leser Format:
  1791. 3*2Ratt_lese AT&T Assembler Variante
  1792. 3*2Rintel_lese Intel Assembler Variante
  1793. 3*2Rdirect_kopiere Assembler-Text direkt in die Assembler-Datei
  1794. 3*1O<x>_Optimierungen:
  1795. 3*2Og_erzeuge kleineren Code
  1796. 3*2OG_erzeuge schnelleren Code (Standard)
  1797. 3*2Or_Registervariablen (enth„lt eventuell noch Fehler)
  1798. 3*2Ou_aktiviere unsichere Optimierungen (siehe Dokumentation)
  1799. 3*2O1_Stufe 1 Optimierungen (schnelle Optimierungen)
  1800. 3*2O2_Stufe 2 Optimierungen (-O1 + langsamere Optimierungen)
  1801. 3*2O3_Stufe 3 Optimierungen (gleich wie -O2u)
  1802. 3*2Op<x>_Ziel-Prozessor:
  1803. 3*3Op1_Optimierungen f�r 386/486
  1804. 3*3Op2_Optimierungen f�r Pentium/PentiumMMX (R)
  1805. 3*3Op3_Optimierungen f�r PPro/PII/c6x86/K6 (R)
  1806. 3*1T<x>_Ziel-Betriebssystem
  1807. 3*2TEMX_OS/2 via EMX (EMX/RSX extender inclusive)
  1808. 3*2TGO32V2_Version 2 von DJ Delorie's DOS extender
  1809. 3*2TLINUX_Linux
  1810. 3*2TNETWARE_Novell Netware Module (clib)
  1811. 3*2TOS2_OS/2 / eComStation
  1812. 3*2TSUNOS_SunOS/Solaris
  1813. 3*2TWDOSX_WDOSX DOS extender
  1814. 3*2TWIN32_Windows 32 Bit
  1815. 6*1A<x>_Ausgabe Format:
  1816. 6*2Aas_Unix o-Datei mit Hilfe von GNU AS
  1817. 6*2Agas_GNU Motorola Assembler
  1818. 6*2Amit_MIT Syntax (alter GAS)
  1819. 6*2Amot_Standard Motorola Assembler
  1820. 6*1O<x>_Optimierungen:
  1821. 6*2Oa_schalte Optimierer ein
  1822. 6*2Og_erzeuge kleineren Code
  1823. 6*2OG_erzeuge schnelleren Code (Standard)
  1824. 6*2Ox_optimiere maximal (enth„lt eventuell noch Fehler)
  1825. 6*2O2_setze Ziel-Prozessor auf MC68020+
  1826. 6*1R<x>_Assembler-Leser Format:
  1827. 6*2RMOT_lese Assembler nach Motorola-Art
  1828. 6*1T<x>_Ziel-Betriebssystem:
  1829. 6*2TAMIGA_Commodore Amiga
  1830. 6*2TATARI_Atari ST/STe/TT
  1831. 6*2TMACOS_Macintosh m68k
  1832. 6*2TLINUX_Linux-68k
  1833. **1*_
  1834. **1?_zeigt diese Hilfe an
  1835. 6*2RMOT_lese Assembler nach Motorola-Art
  1836. 6*1T<x>_Ziel-Betriebssystem:
  1837. 6*2TAMIGA_Commodore Amiga
  1838. 6*2TATARI_Atari ST/STe/TT
  1839. 6*2TMACOS_Macintosh m68k
  1840. 6*2TLINUX_Linux-68k
  1841. **1*_
  1842. **1?_zeigt diese Hilfe an
  1843. **1h_zeigt diese Hilfe ohne Warten an
  1844. ]
  1845. #
  1846. # The End...
  1847. #